The configuration and diagnostics OLED panel 

The configuration panel has been added to simplify some configuration tasks for the installer. It 
has an OLED screen and 5 buttons for control. The Left and Right buttons are used to change 
pages or move to another field within a configuration page when configuring. The Up and Down 
buttons are used on all number fields to increase or decrease the value and the Enter button is 
used to apply changes or to activate a command. 
 
Once the controller is given power the panel will be active. If the screen is blank, it will be in 
screen-saving mode. Tapping any button will awaken the screen and allow you to configure the 
device. 
 

 

 
 
 
 
 
 
 

Figure 3 

The configuration and diagnostics OLED panel. 

 
Various tasks can be performed from the menu system, however only a few tasks will be covered 
in this guide. 
 

NOTE:

 Some functions are password protected and the password must be entered before being 

given access to that function. The default 

password is ‘1234’ – but this can be changed from the 

web interface. When the password is requested you would use the Up and Down buttons to 
change the letter or number shown until it is correct, then Right to move to the next character. This 
process would repeat until the entire password has been entered, then the Enter button is pressed 
to confirm. 
 

 

Содержание SDC-650

Страница 1: ...nputs Up to 16 SDC controllers can be linked using a protected RS 485 network The PC can connect to it using either RS 232 or the built in Ethernet connector or through the RS 485 network from another...

Страница 2: ...SDC 650 Multiple door controller 2 Introduction Copyright 2015 Saflec Systems Pty Ltd http www saflecsystems co za Figure 2 Possible position for an SDC 650 in a SACS access control system...

Страница 3: ...wer the panel will be active If the screen is blank it will be in screen saving mode Tapping any button will awaken the screen and allow you to configure the device Figure 3 The configuration and diag...

Страница 4: ...ations network Each controller on this network requires a unique address for communications and identification Duplicate addresses will cause communication problems The address of the controller can b...

Страница 5: ...and last controller on the line by shorting J6 Controllers in the middle of the line must not have the termination jumper inserted as this can cause network problems In the diagram above you will see...

Страница 6: ...mmunicate with the host system This can be done through either the Ethernet connection or the RS 232 connection The Ethernet cable is a non power over Ethernet cable to an RJ 45 plug The typical wirin...

Страница 7: ...at the controller board with the power connector on the top right of the board the inputs are arranged in ascending order from left to right with a shared common between each input pair See the diagra...

Страница 8: ...for the output relays Figure 12 Example wiring for an externally powered magnetic lock Normally closed Output mode 2 Internally powered outputs To set the output to internally powered mode place two j...

Страница 9: ...loads such as strike locks care should be taken to prevent a back EMF voltage spike In order to do this a freewheeling diode also known as flyback diode should be connected across the load as seen in...

Страница 10: ...Figure 16 The Web interface front page It shows basic diagnostics information on the main page but the links at the bottom will require a username and password for authentication The default username...

Страница 11: ...contact Maximum voltage AC 250Vac Maximum voltage DC 220Vdc Internally powered Outputs Maximum combined current 3 7A Recommended maximums per relay 750mA at 12Vdc Externally powered Outputs Recommende...

Страница 12: ...SDC 650 Multiple door controller 12 Copyright 2015 Saflec Systems Pty Ltd http www saflecsystems co za Notes...

Отзывы: