Roof Reach Portable System

The Roof Reach is a versatile, portable fall protection  

system. It combines easy access at elevated work areas  

such as roofs or 2nd+ floors during construction.  The  

system includes two stationary single point anchors. The 

loops serve as attachment points for the anchorage of a 

Personal Fall Arrest System (PFAS). The system can be 

moved by 4 workers.

The System is held in place at the work location by 4 

retractable jacks.  Two 12" Rubber on cast 360° swivel  

wheels and two 12" rigid rubber on cast wheels make  

moving the unit simple and quick. The unit is comprised of 

power coated or zinc plated components, with zinc plated 

or stainless steel hardware, for high corrosion resistance. 

Total system weight is 1,860 lbs.  with all counterweights installed.

The Roof 

Reach is designed to enable safe working at heights in accordance with current regulations.  

The System is engineered to conform to the requirements of: 

OSHA 1926.502 

ANSI Z359.1 

Содержание FS-EX330-LERF

Страница 1: ...nd maintenance of this component have them explained to you ANY MISUSE OF THIS COMPONENT ANY ALTERATION OR MODIFICATION OF IT OR FAILURE TO PROPERLY FOLLOW THESE USER S INSTRUCTIONS MAY RESULT IN SERI...

Страница 2: ...ystem is held in place at the work location by 4 retractable jacks Two 12 Rubber on cast 360 swivel wheels and two 12 rigid rubber on cast wheels make moving the unit simple and quick The unit is comp...

Страница 3: ...imum rated load for the energy absorbing lanyard SRL The lanyard shall be capable of limiting the fall arrest load to less than 1800 lbs and the SRL shall be capable of limiting the fall arrest load t...

Страница 4: ...Preferably fall arrest equipment like this should when not in use be kept in dedicated cabinets which permit adequate ventilation System Label Prior to accessing the systems the user should always in...

Страница 5: ...n time the anchorages should be placed so that the potential for entangling the vertical lifelines is minimal Care should also be used in selecting a harness Harnesses with sewn down back pads can lim...

Страница 6: ...quipped with side d rings If it is these may be attached to for this type of work Always ensure that the locking mechanism of the snap hook or karabiner is properly closed and incapable of accidental...

Страница 7: ...ner The typical attachment between a user and a single point anchor that is located at the height of the user or lower is via a lanyard See Figure 3 below for an example using a d ring which should ha...

Страница 8: ...mation refer to the Self Retracting Lifeline Instruction Guide in the operation and maintenance manual To attach to the SRL pull the tag line down This will pull the SRL snap hook down to you Slip the...

Страница 9: ...o be sure that it is firm and that roll out is not possible see Figure 1 above If a d ring extender is used the extender is connected to the back d ring of the harness attach the snap hook at the end...

Страница 10: ...nimum installation distance from the side of the unit to the leading edge is 3 ft Anchorage loading is designed such that the angle between the overhead single point attachment on the Roof Reach to th...

Страница 11: ...Part numbers and Assembly Identification 6 7 THE UNIT MUST SIT ON A CLEAN AND DRY SURFACE FRONT JACK FEET SHOUD BE AT LEAST 1 FOOT FROM ROOF EDGE...

Страница 12: ...gning the holes in the back of the arm assembly with the holes in the front of the mast assembly and pin in place with two pins Step 4 Raise mast assembly until the hole in the bottom of the mast asse...

Страница 13: ...front and rear assembly and pin in place using one pin Step 7 Pull pins from body front and body rear assembly at the wheels and telescope outriggers out until the far holes on the outriggers line up...

Страница 14: ...ll four leveling jacks until the wheels of the unit are off the surface Using the level located on the body front assembly make sure the unit is level Step 10 Attach SRLs to the loop connections at th...

Страница 15: ...A 1926 502 regulations Warning Failure to read and follow product instructions could result in serious personal injury or death Training and instruction review should be repeated at regular intervals...

Страница 16: ...els Attention labels located on the Arm of the Roof Reach system Deployment warning located on the body of the Roof Reach system Counterweight warning located on the back of the unit between the pushi...

Страница 17: ...Contact Information SAFEWAZE 322 Industrial Court Concord NC 28025 Phone 704 262 7893 Fax 262 262 9051 Email info safewaze com www safewaze com...

Страница 18: ...rm water and a mild detergent Ensure that the parts are rinsed thoroughly with plenty of clean water Although highly resistant to chemicals and environmental conditions take all precautions to avoid c...

Страница 19: ...del No Mfg Date SAFEWAZE 704 262 7893 Date Condition of System Inspected By Maintenance 1 Inspect all hardware for distortion and deformation Check for visible cracks excessive wear and tear corrosion...

Отзывы: