SafeWaze FS-EX311 Скачать руководство пользователя страница 2

  

322 Industrial Court, Concord NC, 28025

  

Phone: 704-262-7893

  

Email: [email protected]

  

Web: safewaze.com

 

 Fax: 704-262-9051

I

I

I

I

I

INSTALLATION

INSTALLATION EXAMPLE

FS-EX311 STANDING SEAM ROOF ANCHOR COMPONENTS

WARNING

 

    

   

•  Users should consult with their doctor to verify ability to safely absorb the forces of a fall arrest event.  

Fitness level, age, and other health conditions can greatly affect an individuals ability to withstand fall 

arrest forces. Women who are pregnant, individuals considered minors must not use any SAFEWAZE™ 

equipment. 

•  Never alter any part of a lanyard or add/remove components.  SAFEWAZE™ shall not be held 

responsible for injury or death due to tampering.

•  Anchors that are exposed to fall arrest forces MUST be IMMEDIATELY removed from service and 

destroyed.  

•  Failure to follow these instructions and warnings could result in serious injury or death in the event 

of a fall.

•  A preplanned rescue procedure in the event of a fall is required.  The rescue plan must be specific to 

the project.  The rescue plan must allow for employees to rescue themselves, or to be promptly rescued 

by alternative means. 

•  Harnesses or connectors selected for use with any SAFEWAZE™ anchor must be compatible in size 

and configuration. User must ensure compatibility of snap hooks, carabiners and other connectors.  Any 

connection which could allow disengagement must be eliminated. Snap hooks and carabiners must be 

self locking and self closing and must never be hooked to each other. 

•  A Competent Person must conduct an analysis of the workplace and anticipate where workers will be 

conducting their duties, the route they will take to reach their work, and the existing and potential fall 

hazards they may be exposed to.  The Competent Person must choose the fall protection equipment 

to be utilized.  

•  Do not misuse equipment.

•  Equipment designated for fall protection must never be used to lift, hang, support or hoist tools or 

equipment unless specifically certified for such use.    

•  SAFEWAZE™  Anchors shall be inspected prior to each use by the user and at least every 6 months 

by a Competent Person.  Annual inspections shall be documented.  Severity of conditions during use 

may neccesitate increased frequency of documented inspections.  

•  Anchors that fail inspection MUST be removed from service.

•  Prior to each use, inspect the FS-EX311 Satnding Seam Roof Anchor for deficiencies or damage, 

including, but not limited to, sharp edges, rough edges, deformations, corrosion, pits, burrs, chemical 

exposure, extreme heat exposure, or missing or illegible labels. If any deficiencies or defects are found, 

the FS-EX311 must IMMEDIATELY be removed from service.

•  The FS-EX311 Standing Seam Roof Anchor must be inspected at least every 6 months by a 

Competent Person other than the user.  Competent person inspections must be recorded in the 

inspection log included in this manual and on the inspection grid label on the FS-EX311. 

INSPECTION

MAINTENANCE & STORAGE

WARRANTY

The FS-EX311 Standing Seam Roof Anchor can be cleaned with water and mild soap if necessary.  User 

should remove all dirt, possible corrosives, and contaminants from the anchor prior to, and after each 

use.  Never use any type of corrosive substance to clean the FS-EX311.  

Excess water should be blown out with compressed air.  Hardware can be wiped off with a clean, dry 

cloth.

When not in use, store the FS-EX311 Standing Seam Roof Anchor in a cool dry area where it will not 

be exposed to extreme light, extreme heat, excessive moisture, or possibly corrosive chemicals or 

materials.   

SAFEWAZE™ warrants its products are free from defects in materials and construction under normal 

use and service.  Liability is not accepted for abuse, modification, improper use, destructive activity and 

contaminated exposure. 

INSPECTION LOG

Date

Inspection Items 

Noted

Corrective Action

Initials

LABELS

1. Under guidance of a Competent or Qualified Person, a suitable anchor point must be chosen that 

meets the strength requirement, minimizes free fall, and reduces swing fall hazards. Do not work above 

the anchorage point.

2. The FS-EX311 Standing Seam Roof Anchor can be installed on any structure that meets the strength 

requirements as defined in the SPECIFIC ANCHOR APPLICATIONS section of this manual for Personal 

Fall Arrest.

3. The FS-EX311 Standing Seam Roof anchor is a rated roof anchor point designed for sloped or flat 

roofs. The Standing Seam roof deck must be rated to meet OSHA, federal, state, and local government 

regulations for fall protection anchor points.  MINIMUM required substrate thickness is 24 gauge.  

4. The FS-EX311 Standing Seam Roof Anchor is NOT suitable for use with Horizontal Lifelines.

5. To install the FS-EX311 Standing Seam Roof Anchor the user will first loosen the 4 Tightening Bolts. 

This allows the two side plates to seperate a sufficient distance for installation onto the standing seam   

(See Figure 6).

6. Once the FS-EX311 is opened wide enough to allow the standing seam to be enclosed in the anchor, 

the user will then tighten the bolts to 50 ft. lbs. starting with the top two bolts first (See Figure 7).  Once 

all bolts are tightened, the bolts should be loosened once again and retightened on the standing seam. 

This ensures proper compression of any open space within the seam.    

7. The allowable working radius of the FS-EX311 Standing Seam Roof Anchor is 30° in line with the 

anchor (See Figure 8).

FIGURE 5 - ANCHOR COMPONENTS

FIGURE 6 - INSTALLATION

FIGURE 7 - INSTALLATION

FIGURE 8 - ALLOWABLE WORK RADIUS

322 Industrial Court, Concord, NC 28025

(704) 262-7893  |  www.safewaze.com

MODEL #: FS-EX311

SINGLE STANDING SEAM 

ROOF ANCHOR

MEETS OSHA 1926.502;

ANSI Z359.1 & ANSI A10.32

MUST FOLLOW MANUFACTURER’S 

INSTRUCTIONS INCULDED WITH 

EQUIPMENT.

DO NOT REMOVE LABEL.

Total working weight: 310 lbs        Material: Carbon steel        Minimum breaking strength: 5000 lb / 2268 kg

INSTRUCTIONS:

Adjust leg of anchor to align with the spacing of roof seam (min 4 ft / 1.22 m from edge). Bent side of clamps must be hooked underneath lip of 

seam; flat sides must be flush with flat side of seam before tightening. Tighten clamps to secure assembly to metal deck seam. Torque each bolt 

to 50 lbs. Top 2 bolts first, then bottom 2 bolts.

MONTH

YEAR
2018

2023

2022

2021

2020

2019

Jan

Feb

Mar

Apr

May

Jun

Jul

Aug

Sep

Nov

Oct

Dec

MANUFACTURING DATE

18

20

19

21

22

23

Jan Feb

Dec

Nov

Oct

Sep

Aug

Jul

Jun

May

Apr

Mar

INSPECTION LOG

01064R3

UNIT MUST BE INSPECTED BEFORE EACH USE. REMOVE FROM SERVICE IF SUBJECTED TO FALL ARREST FORCES.

       ATTENTION:

Only make compatible connections. Avoid all physical hazards, inculding, but not limited to: thermal, electrical and chemical sources. Failure to 

follow all warnings or misuse of equipment could result in serious injury or death.

B

C

D

E

PFAS Attachment Point

Side Plate

Seam Clamp Point

Side Plate

Tightening Bolts

FS-EX311 Standing Seam Anchor Components

A

30° 30°

D

E

C

B

A

Loosen

Tighten

Standing 