Installation of SafetyLink Anchor Points 

(Full Installation Guide available from website www.heightsafety.com )

 

 

 

 

 

 

 

READ ENTIRE HANDBOOK BEFORE INSTALLING ANY SAFETYLINK PRODUCT. 

ALL PRODUCTS MUST BE INSTALLED IN ACCORDANCE WITH SAFETYLINK’S INSTALLATION 

HANDBOOK, USING ONLY PRODUCTS SUPPLIED BY SAFETYLINK PTY LTD.

 

 

FAILURE TO FOLLOW ALL WARNINGS AND INSTRUCTIONS MAY RESULT 

IN A SERIOUS INJURY OR DEATH. 

 

If you are uncertain and need help please email: [email protected]  

Phone: 1300 789 545 or +61 249 972272 | Fax: 1300 738 071 or +61 249 971104 

 or visit our website www.heightsafety.com  

 

 

 

 

 

 

 

 

 

 

 

Manual   

 

 

 

 

 

 

 

 

 

 

Catalogue 

Содержание TileLink

Страница 1: ...DUCTS MUST BE INSTALLED IN ACCORDANCE WITH SAFETYLINK S INSTALLATION HANDBOOK USING ONLY PRODUCTS SUPPLIED BY SAFETYLINK PTY LTD FAILURE TO FOLLOW ALL WARNINGS AND INSTRUCTIONS MAY RESULT IN A SERIOUS INJURY OR DEATH If you are uncertain and need help please email safetylink heightsafety com au Phone 1300 789 545 or 61 249 972272 Fax 1300 738 071 or 61 249 971104 or visit our website www heightsaf...

Страница 2: ...NCE PERIODIC INSPECTIONS 4 WARRANTIES 5 TILELINK ANCHOR UNIT 6 PRODUCT CODE TILEL001 6 FITTING THE ANCHOR POINT 7 INSTALLATION OF TILELINK ERROR BOOKMARK NOT DEFINED APPENDIX 8 DIAGRAM 2 POSITIONING LAYOUT 8 DIAGRAM 3 POSITIONING LAYOUT 9 NOTES 10 NOTES 11 IN CASE OF ACCIDENT 12 Click to go to YouTube Install Video ...

Страница 3: ...roof tiles Sika Flex Co Polymer Sealant Recommended waterproofing for metal roof Silicone Sealant All threads must be coated with Loctite prior to assembly IMPORTANT NOTE Before applying Loctite 243 use Loctite 7471 primer to activate the surface according to manufacturer s instructions MAXIMUM USER PER EYEBOLT IS ONE 1 WARNING Locking Hex Nut must be fully screwed up the thread of the eyebolt to ...

Страница 4: ...ound the rafter and the bottom fixing point will be pulled out and the anchor will need to be replaced The eyebolt should remain straight a bent eyebolt will indicate that the anchor point has arrested a fall The design features of the eyebolt includes the ability to bend like a fishing pole starting from the top and working its way to the bottom enabling it to use up energy as the eyebolt bends w...

Страница 5: ... for a period of 1 one year from the date of shipment This limited warranty applies provided that a defects have arising solely from faulty materials or workmanship b the Products have not received maltreatment inattention or interference c the Products have been installed in accordance with the Company s Installation Handbooks using only products supplied by the Company d accessories used with th...

Страница 6: ...2 and 3 The first TileLink anchor point must be in a position easily and safely reached by a secured ladder or a manhole access point INSPECT THE TIMBER FOR STRENGTH Install anchors only to timber strong enough to support the anchor point Minimum timber size is 35mm by 90mm grade F5 Inspect the timber for splits cracks knots and white ant damage Ensure the timber structure is secured in accordance...

Страница 7: ...re of the rafter 3 Pump silicone between the anchor plate and the bottom tile 4 Secure TileLink plate to the rafter using five 5 x 12 gauge 50mm roofing screws Pilot holes must be drilled into the timber the full length of each screw to avoid splitting the timber 5 Put more silicone onto the top of the anchor plate and also on the bottom tile on either side of the anchor plate and also across the ...

Страница 8: ...gth Please contact your distributor if you are unsure ACCESS LAYOUT AND USE OF A SAFETYLINK ANCHOR SYSTEM SafetyLink anchor points are positioned by calculating the pendulum effect this limits the likelihood of a fall past the edge of the roof space The pendulum effect still applies to a flat roof SAFETYLINK HEIGHT SAFETY SYSTEMS must only be installed as per our installation guides to structures ...

Страница 9: ...gth Please contact your distributor if you are unsure ACCESS LAYOUT AND USE OF A SAFETYLINK ANCHOR SYSTEM SafetyLink anchor points are positioned by calculating the pendulum effect this limits the likelihood of a fall past the edge of the roof space The pendulum effect still applies to a flat roof SAFETYLINK HEIGHT SAFETY SYSTEMS must only be installed as per our installation guides to structures ...

Страница 10: ...Click back to Table of Contents Handbook_TileLink Version 03 16 Page 10 of 12 NOTES ...

Страница 11: ...Click back to Table of Contents Handbook_TileLink Version 03 16 Page 11 of 12 NOTES ...

Страница 12: ...ential to remove the person from the suspended position as quickly as possible In accordance with AS NZS 1891 4 2009 clause 9 5 EQUIPMENT WHICH HAS ARRESTED A FALL OR SHOWS A DEFECT Any piece of equipment including both personal and permanently installed items which has been used to arrest a fall or which shows any defect during operator or periodic inspection shall be withdrawn from service immed...