EXAMPLE: HORIZONTAL LIFELINE ON PITCHES BELOW 25 DEGREES
All working at heights safety procedures must be complied with when installing SafetyLink Height Safety Systems. For more
information refer to your state or territories current legislation, regulations, policies and codes of practices. Horizontal height
safety lifelines must only be installed and used by competent people with relevant current height safety qualifications.
SAFETYLINK HEIGHT SAFETY SYSTEMS MUST ONLY BE INSTALLED AS PER OUR INSTALLATION GUIDES, TO
STRUCTURES AS SPECIFIED IN THE INSTALLATION MANUAL FOR EACH PRODUCT. SHOULD ANY DOUBT EXIST IN
REGARD TO THE STRUCTURES INTEGRITY AN ENGINEER SHOULD BE CONSULTED.
FrogLine
Intermediate Unit
FrogLine End Unit and
Tensioner with Tension indicator
FrogLine
Corner Unit
FrogLine Intermediate Unit
WARNING:
Surface Mounted Anchors
should be positioned
two 2 metres from the edge
on clip down/standing seam
style roof profiles unless
additional securing of roof
sheeting is made.
C
abl
e
MAXIMUM SPACE BETWEEN
INTERMEDIATE ASSEMBLY IS
TEN (10) METRES