1. Make sure key switch is in the OFF
position.

2. Remove cover from base unit by
applying pressure to the key barrel. 
Ensure that the tamper screw located 
on the bottom right hand side is removed
by using the tamperproof tool provided.

3. Set switches, on circuit board, to desired 
alarm settings (figure 4 see over).

4. Mount base unit on or next to door using
the 2 fixings provided. (See Dia. A for 
recommendation*). Reed switch mounting
locations can be moved to the four positions
shown in Dia. A. If mounted next to door,
route reed switch wire through knockout in
bottom of housing as shown in figure 2.

5. Mount magnet on door frame (or door if 
unit is mounted next to door) using screws
provided. When mounting on metal doors 
or door frames, use plastic spacer provided.
Reed switch and magnet must be within 
13mm/1/2" when door is closed. Please refer
to figures 5, 6 and 7 for other mounting options.

6. To fix the cover to the base unit, hooks 
can be found on the inside top edge of the
cover. Insert the hooks into the slots provided
on the edge of the base unit (see Dia. B) and
snap the cover down until it clicks into place.
Using the tamperproof tool provided insert
and tighten the screw to secure the cover to 
the base (see Dia. C).

7. REMOVING THE COVER FROM THE BASE
Remove the tamper screw located on the bottom
right hand side with the tamperproof tool provided. 
Apply pressure to the key barrel. Keep the 
tamperproof tool safe for future servicing and 
battery change. 

 

 

 

EXIT STOPPER

A completely self-contained security system that provides a highly effective, extremely versatile and
inexpensive way to help prevent unauthorised use of fire/emergency doors. The EXIT STOPPER is
supplied with an installation kit and 9v alkaline battery. It also incorporates a key override facility for
authorised use.

 SCREW 

6 x 1 1/4 in. 

(2) PROVIDED 

SHOWN 

BOTTOM SURFACE AS 

WIRES THROUGH NOTCH O N 

AND ROUTE REED SWITCH 

REMOVE FRONT COVER 

(USED AS NECESSARY) 

SPACER S 

NOTE: 2 SPACERS UNDER BOTH 

MAGNET AND REED SWITCH 

MUST BE USED ON STEEL DOORS 

VIEW SHOWING MAGNET INSTALLATION 

NB: FITTING UNIT AWAY FROM DOOR (OPTIONAL) 

MAGNET 

13mm [1/2 in.] 

MAXIMUM GA P 

FIGURE 2 

 

Need help? Call our Technical Support Team on +44 (0)1527 520 999 

INSTALLATION DATA FOR THE STI-6400 & STI-6400/WIR

 

Housing 

3mm 1/8" polycarbonate

Power Source 

9 VDC Alkaline

Sounder Output 

95 dB - low/105 dB - high

Relay Output 

9 VDC, 40mA

Dimensions 

136mm/5.35" h x 136mm/5.35" w x 50mm/1.97" d

Standby Current 

10uA

Alarm Current 

200mA

SPECIFICATIONS

 

STI-6400 

Exit Stopper

STI-6402 

Exit Stopper Double Door

STI-6400/RK 

Remote Kit

STI-6400/RS 

Remote Sounder

PART No.

EXIT STOPPER PART NUMBERS

PRE INSTALLATION CHECKLIST

IMPORTANT NOTICE: If you have purchased a STI-6400/WIR model, before installation you will need
to ‘learn’ the transmitter to the 8 channel receiver. Please refer to the Quick Setup Guide. Once‘learned’,
follow steps 1-7 opposite.

DO YOU WANT HIGH OR LOW SOUNDER OUTPUT?

The Exit Stopper is factory set for HIGH sounder output (105 dB). To change the unit to a LOW output 
(95 dB), locate JP2 and move to the OFF position.

DO YOU WANT THE EXIT STOPPER TO ALARM IMMEDIATELY?

The Exit Stopper is factory set to arm immediately after the key is turned to the ON position. You can
change this to a 15 second arming delay. This feature allows an authorised key holder to turn the unit 
on and then exit through the door before the unit arms. To set a 15 second arming delay move jumper 
JP7 to the OFF position.

DO YOU WANT THE EXIT STOPPER TO ACTIVATE IMMEDIATELY THE DOOR IS OPENED?

The Exit Stopper is factory set to activate immediately the protected door is opened. The unit can be 
set for a 15 second delay. This would allow an authorised key holder to open the door and turn the Exit
Stopper off before it activates. To set to a 15 second activation delay move the jumper to JP5 to the ON
position.

SOUNDER OUTPUT OPTIONS

The Exit Stopper is factory set to sound for 30 seconds once activated. There are three other settings, 
180 seconds, continuous and 5 beeps.

 

STI F021 

STI CO23/A 

STI BAT1 

STI L6400 

ACCESSORIES 

DIA. B 

PART No.

PC BOARD 

REED SWITCH 

REED SWITCH MOUNTING 

KEY  

(2) PROVIDED 

           

OUTER COVER

NOTE:

 TO SELECT ALARM OPTIONS,

REMOVE OUTER COVER AND FOLLOWING

THE SWITCH SETTINGS CHART, SHOWN ON

REVERSE SIDE, CHOOSE THE ALARM

OPTIONS SUITABLE FOR EACH INSTALLATION.

SCREW #8 x 1 in. 

(2) PROVIDED 

USING BACK PLATE AS  

TEMPLATE MARK AND DRILL 

(2) 4.7 mm [3/16 in]  DIA. HOLES 

RAWL PLUG 

(2) PROVIDED 

SHOWN IN FACTORY 

INSTALLED POSITION 

9 VOLT 

ALKALINE 

BATTERY 

KEY SWITCH 

4 FIXING HOLES  

DIA. A 

SLOT 

 

PEGS. (4 OPTIONAL POSITIONS) 

 

SLOT 

SCREW 
TAMPER-PROOF 
(1) PROVIDED 

TAMPER 

PROOF TOOL 

(1) PROVIDED 

DIA. C 

 

FIGURE 1 

*recommendation  

for the fixings 

ID6400-6400WIR · Revised 10/16-001 · Printed in England

SLOT 

HOOK 

VIEW SHOWING HOW TO FIX THE COVER TO THE BASE 

FIGURE 3 

Need help? Call our Technical Support Team on +44 (0)1527 520 999 

Safety Technology International

Taylor House, 34 Sherwood Road, Bromsgrove

Worcestershire, B60 3DR, England
Telephone: +44 (0) 1527 520 999

Fax: +44 (0) 1527 501 999

E mail: [email protected]  Web Site: www.sti-europe.com

Emergency Exit Warning Sign

9 V Battery

Spare Keys

Tamperproof Tool

DESCRIPTION 

DESCRIPTION 

Отзывы: