background image

 

 

                                                                                          

 

 

Page 20

 

 

deviation concerns the SafeRail Carriage-safety carriage, the carriage must be replaced, and the old 
carriage removed from use. If the deviation affects any other parts of the system, they must be repaired or 
replaced depending on the type of deviation.  

6.1 

COMMISSIONING INSPECTION 

Before the SafeRail-fall arrest system is taken into use or after repairs have been performed to the system, a 
commissioning inspection must be carried out, during which the entire system and its individual components 
are inspected.  

Commissioning inspections must be documented.  

During the commissioning inspection, the inspector examines whether the installation has been carried out 
according to the instructions, whether each fixing and tensioning has been performed carefully, and whether 
the system and its components are undamaged. As part of the commissioning inspection, the system must 
be tested by ascending and descending the entire length of the Vertical SafeRail-safety rail using a SafeRail 
Carriage-safety carriage. 

6.1.1 

COMMISSIONING INSPECTION 

– SAFERAIL CARRIAGE-SAFETY CARRIAGE AND 

ITS FUNCTIONALITY 

 

The spring of the SafeRail Carriage-safety carriage is undamaged and springy. 

 

The spring of the SafeRail Carriage-safety carriage is properly in place and functional. The condition 
of the spring must be verified by coupling the carriage with and moving the carriage along the 
Vertical SafeRail-safety rail and letting go. After falling, the SafeRail Carriage-safety carriage will lock 
automatically on to the locking notches if the spring is working as expected. The Vertical SafeRail-
safety rail is equipped with locking notches every 150 mm. 

 

The SafeRail Carriage-safety carriage has not been deformed in any way. 

 

The wheels of the SafeRail Carriage-safety carriage are tightly attached to the axels, and it glides 
effortlessly along the Vertical SafeRail-safety rail. 

 

The permanent markings on the SafeRail Carriage-safety carriage are clearly legible. 

6.1.2 

COMMISSIONING INSPECTION 

– SAFERAIL LADDERS AND VERTICAL SAFERAIL- 

SAFETY RAIL 

 

The structures of the SafeRail ladder and/or the Vertical SafeRail-safety rail are undamaged. In 
order to check that the SafeRail ladder and/or the Vertical SafeRail-safety rail have been installed 
correctly, the user must also review the installation instructions. 

 

The structures to which the SafeRail ladder and/or the Vertical SafeRail-safety rail have been 
attached are undamaged. 

 

No mechanical or corrosion/rust damage can be observed on the Vertical SafeRail-safety rail. 

 

The groove on the Vertical SafeRail-safety rail profile has the correct width, i.e. 15 mm. 

 

The screws, bolts, and nuts of the fasteners and the extension pieces used to secure the SafeRail 
ladder and/or the Vertical SafeRail-safety rail are safely and securely attached. 

 

The markings on the instructional sign of the SafeRail-fall arrest system are up to date and clearly 
legible. Order a new sign if necessary. 

 

The commissioning inspection must also always include a test climb with a SafeRail Carriage-safety 
carriage. 

Содержание MM 111

Страница 1: ...INSTALLATION MANUAL...

Страница 2: ...Fasteners used for installation 5 3 4 Fixing distances 5 3 5 Joining of Vertical SafeRail safety rails 6 3 6 Ground Clearance 6 3 7 Installation of SafeRail Carriage Stopper carriage barriers 6 3 8 In...

Страница 3: ...maximum and minimum weight of the user the number of users the distance between users and the minimum operating temperature before each use 14 1 4 Ensuring other key factors of work safety before eac...

Страница 4: ...u have the appropriate tools and safety equipment required available for the installation Also make sure that the necessary preparations and work safety measures have been carried out before you begin...

Страница 5: ...section of the ladder amounting to a maximum of 1500 mm may be left unsupported at the bottom of the Handrail Ladder MM 122 2 5 JOINING OF SAFERAIL LADDER ELEMENTS The SafeRail Joint extension piece...

Страница 6: ...carriage barrier MM 312 and the fixed Carriage Stopper carriage barrier MM 313 Carriage Stopper carriage barrier MM 311 is designed to be used at the bottom end of SafeRail ladders and or Vertical Sa...

Страница 7: ...g the SafeRail fall arrest system The instructional sign must be installed in such a manner that it is easy to spot and clearly visible to the user before using the system The installation month and y...

Страница 8: ...mp rail fastener Attach the locking screw of the SafeRail Clamp rail fastener When tensioning the locking screw ensure that the groove of the safety rail remains at a width of 15 mm The locking screw...

Страница 9: ...ier MM 312 you must also always install the Carriage Guide carriage guide MM 301 which ensures that the SafeRail Carriage safety carriage is coupled with the safety rail in the correct position 6 1 IN...

Страница 10: ...on to the safety rail such that it is placed against the back of the safety rail and the latch of the stopper opens up on to the right side 2 The Carriage Stopper carriage barrier MM 311 must be inst...

Страница 11: ...riage must remain on the left side of the carriage as the carriage is slid on to the rail and the Up arrow engraved on the carriage must point up 9 USE AND INSTALLATION OF THE CARRIAGE STOPPER CARRIAG...

Страница 12: ...Rail safety rails with each other 10 1 INSTALLATION OF THE SAFERAIL JOINT EXTENSION PIECES MM 201 1 Check that the ends of the safety rail are properly attached and placed level with each other 2 Inst...

Страница 13: ...d nuts of the fasteners and the extension pieces used to secure the SafeRail ladder and or the Vertical SafeRail safety rail are safely and securely attached The spring of the SafeRail Carriage safety...

Страница 14: ...y rail instead of the top end there is a risk that the SafeRail Carriage safety carriage may come off the safety rail accidentally in which case the user may fall At the bottom end of the safety rail...

Страница 15: ...helmet and safety shoes Before using the system prepare for potential accidents and plan how to act in a hazardous situation The relevant rescue procedure must be immediately available and realizable...

Страница 16: ...he anchorage points and the performance of the work must be planned out such that the potential for a fall and the potential falling height are minimized During climbing the user must lean back to all...

Страница 17: ...eratures while wet Also note that SafeRail Carriage safety carriages designed for horizontal use can never be used for vertical climbing If atypical wear is noticed on a SafeRail Carriage safety carri...

Страница 18: ...SafeRail Carriage safety carriage 3 2 SAFERAIL LADDERS AND VERTICAL SAFERAIL SAFETY RAILS SafeRail ladders and Vertical SafeRail safety rails retain their functionality without any special maintenance...

Страница 19: ...ion of coupling of the carriage UP the marking can be found on the front side of the carriage A marking advising the user to read the user instructions the marking can be found on the front side of th...

Страница 20: ...Symbol urging the use a full body harness Reminder to read the user instructions Standard number EN 353 1 2014 A1 2017 CE body identification number CE 0403 SafeRail trademark Name and address of the...

Страница 21: ...etting go After falling the SafeRail Carriage safety carriage will lock automatically on to the locking notches if the spring is working as expected The Vertical SafeRail safety rail is equipped with...

Страница 22: ...the system is used again SafeRail ladders and Vertical SafeRail safety rails must also be inspected after each falling incident before the next use Please note that in case of a fall the SafeRail Car...

Отзывы: