Страница 2: ...ic keypad press the key once for the first letter twice for the 2nd etc Please note that the 0 key if pressed twice will display a space The navigation keypad is used to move between the menus using t...

Страница 3: ...n battery saving software to facilitate the longest possible use between charges The instrument will therefore power down after a period of 10 minutes of inactivity If the instrument is in a logging m...

Страница 4: ...Start up Screen The start up screen is displayed briefly on power up and displays the following information Serial Number Software version no Time Date...

Страница 5: ...is displayed the Home screen appears This screen displays the following information Counts reading Sensitivity setting Battery status icon Menu icon Charging if connected to the charger note the batte...

Страница 6: ...displayed on the Home screen 1 the temperature of the instrument is displayed in degrees Centigrade this is also output in the data log against each record 2 The sample number generated each time the...

Страница 7: ...n arrow on the navigation key pad The menus allow setting of the following options Set Sensitivity High Med Low Zero Calibration On Off Backlight timer On Off Logging Start time Interval Upload delete...

Страница 8: ...variety of different conditions where the amount of contamination present may vary considerably The Sensitivity level is selected from the main menu by pressing option 1 for LOW 2 for MEDIUM and 3 fo...

Страница 9: ...o 4 on the menu screen The screen will return to the home screen and the counts display will read 0000 Subsequent readings will then be displayed having had the background subtracted To remove the zer...

Страница 10: ...will now turn off after 5 minutes operation press any key to turn back on To turn the backlight timer off ie to have the backlight constantly on select 6 again from the menu The display will now show...

Страница 11: ...o 2000 records provided the memory has been cleared before sampling begins To access the logging setup press the down arrow to access the first menu and then press the down arrow again to access the 2...

Страница 12: ...ERVAL Enter the interval using the keypad and use the arrows to move the cursor to the next digit as required press OK to save If you wish to write the data immediately to a pc from the 2nd menu scree...

Страница 13: ...location press OK to save To set a unique reference repeat as above selecting no 2 from the menu and press OK to save To start the log running select no 1 START TIMED LOGGING from the 2nd menu note yo...

Страница 14: ...ome screen will now show that logging is on and the interval selected The SMF4 may be turned off the logging will start and continue without the display being on To stop logging select no 1 STOP TIMED...

Страница 15: ...e and ensure that you can receive data On the 2nd menu screen select No 4 UPLOAD DATA LOG The screen will now show how many records there are to download press OK to start the download Once downloaded...

Страница 16: ...n 3 from the 3rd menu screen Use the keypad to enter the time in 24 hour format the arrow on the navigation keypad moves the cursor between digits The date is set for UK format of DD MM YY Once comple...

Страница 17: ...o the 3rd menu screen as shown opposite The desired backlight level can be selected by pressing 4 low 5 medium or 6 high as light conditions dictate please note that the backlight has a significant dr...