Error/Warning Codes Troubleshooting Table
The table is provided to assist in tracking down system problems, it is not meant to take the place of good
troubleshooting practices.
Accumax Display Controller Errors and Warnings
Code
Message
Description/Cause
Corrective Actions
E0001
NO DATA
Data cable unplugged.
Wiring issue.
Missing CAN network terminator.
Other hardware not powered or failed.
Check network connections.
Check/install terminators if missing.
Contact manufacturer.
E0010
E0011
E0012
SOFTWARE DRIVER FAILED
INTERNAL ERROR
Unit encountered internal error
Restart unit.
Check for latest firmware updates.
Contact manufacturer.
W0020
HIGH TEMP WARNING
High temperature inside of the unit
Unit will operate normally.
Action will be required if temperature continues
to rise.
W0021
UNIT TOO HOT!!!
Internal temperature reaching thermal
shutdown level.
Reduce heat exposure
Accumax Network Assembly Errors and Warnings
E0403
NO INJECTOR
Injector not detected.
Injector not paired.
Injector not powered.
Injector cable disconnected.
Injector hardware issue.
Pair injector.
Check wiring and power to injector.
Contact factory.
E0404
NETWORK CONFLICT
Multiple injectors with the same ID on the
network.
Pair injector.
E0405
NO LOW-FLOW
Low-Flow hardware not detected.
Low-Flow not paired yet.
Low-Flow not powered.
Low-Flow cable disconnected.
Low-Flow hardware issue.
Pair Low-Flow.
Check wiring and power to Low-Flow.
Contact factory.
E0406
NETWORK CONFLICT
Multiple low-flow hardware in the same
Group on the network.
Pair Low-Flow.
E0407
NO HYD. CONTROLLER
Hydraulic Controller hardware
not detected.
Hydraulic Controller not paired.
Hydraulic Controller not powered.
Hydraulic Controller cable disconnected.
Hydraulic Controller hardware issue.
Pair Hydraulic Controller.
Check wiring and power to Hydraulic
Controller.
Contact factory.
E0408
NETWORK CONFLICT
Multiple Hydraulic Controllers hardware
in the same Group on the network.
Pair Hydraulic Controller.
Accumax Injector Assembly Errors and Warnings
E0430
INJ. PRESS. SENSOR
Injector assembly pressure sensor failed
or disconnected.
Check if sensor is installed and plugged in.
Check pressure sensor wiring.
Replace pressure sensor.
E0431
INJ. HARDWARE CAL.
Injector assembly calibration issue.
Calibration incorrect or not performed.
Recalibrate foam flow on this
injector assembly.
E0432
INJ. HDW. OVERCURRENT
Injector assembly hardware
overcurrent detected.
Inspect injector assembly metering valve for
foreign objects.
Flush injector.
Contact factory if issue persists.
E0433
INJ. HDW. ENCODER
Injector assembly hardware issue.
Position encoder issue.
Injector assembly internal issue
contact factory.
E0434
INJ. HDW. STALL
Injector assembly motor stall. detected.
Check if injector assembly has sufficient power
to operate.
Reset power.
Check if all cables are securely connected.
If problem persists, contact factory.