MAX100/200-OPERATION Rev200813
38
9. USER SETTINGS
Adjusting User Settings
Reset Accumulated Water and Foam Totals
AccuMax hardware components measure and collect consumption data on water and foam. These numbers are
recorded in an event log each time the system is turned off. These totals are automatically reset at startup. However, they
can be reset at any time from the menu.
1. Select
USER SETTINGS
on the menu screen. Press
INCREASE
or
DECREASE
button until the user setting
is selected. Press
SELECT
button to access the submenu options.
2. Select the
RESET TOTALS
item from this list. Press
SELECT
button to initiate reset.
3. Confirm reset by pressing the
SELECT
button after the dialog box appears.
Water Valve Preset (MAX200 Fusion model only)
The most frequently used water valve position can be programmed and recalled as a preset.
Programming Preset in Operator's Screen:
1. Using the
SELECT, INCREASE
or
DECREASE
buttons, move the valve to the desired preset position.
2. Press and hold the
INCREASE
or
DECREASE
button for approximately 5 seconds. Current valve position
will be saved as the new preset.
3. The preset indicator will move to the new preset value.
Discharge Name Configuration
The display module can be set to display a custom name to identify the discharge it is used with. This name can
be selected from a predefined list or a custom name can be created. This name will be displayed in the Header bar in the
Operator screen.
1. Select USER SETTINGS on the menu screen by pressing the
INCREASE
or
DECREASE
button. Press the
SELECT
button to access this menu.
2. Select the NAME menu with the
INCREASE
or
DECREASE
button and press the
SELECT
button to enter
this menu.
3. To choose a predefined name, select menu item 'SELECT FROM LIST'. Press the
SELECT
button to enter
names list.
4. Select the desired name with the
INCREASE
or
DECREASE
button and press the
SELECT
button change
the setting.
5. To create a custom name from 'NAME' menu, select EDIT NAME. Press
the
SELECT
button to enter 'EDIT NAME' screen. When screen is loaded,
current name is displayed and highlighted for editing.
6. If name is highlighted for editing, use the
SELECT
button
to change to the next character at the cursor position. Use
ON/OFF
button to select the previous character in the cursor position.
Use the
INCREASE
or
DECREASE
button to move the cursor to the
next position. Pressing and holding the
SELECT
or
ON/OFF
buttons
will cycle through available characters automatically.