Phoenix G2 IDU User Manual
WEB GUI
SAF Tehnika JSC
65
Status
Counters
Modem
This section displays basic modem performance counters and built-in Bit Error Rate (BER)
counters. For BER counter only unassigned capacity will be used (Refer to
Figure 3.18
“
Status
Counters
Modem” page
1)
FEC RX Blocks
– the overall number of received airframes
2)
FEC Corrected Blocks
– the number of air-frames which were repaired by FEC (Forward
Error Correction). This number represents a fragment of the FEC RX Blocks
3)
FEC Uncorrected Errors
– the number of air-frames which could not be repaired by FEC.
This number represents a fragment of the FEC RX Blocks
4)
Uncorrected
–
Last Second
– the number of air-frames which could not be repaired
during the last second
5)
FEC Global Rate
– the ratio of FEC Uncorrected Errors / FEC RX Blocks
6)
FEC Actual Rate
– same as above but for latest second only
7)
Uncorrected TLE
– time since last error; a number of seconds from the last error
occurrence. It should correspond to the time since pressing the
button
8)
Uncorrected TBE
– time between last two error events
9)
Uncorrected EFS
– error free seconds; it should correspond to time since pressing the
button
10)
Uncorrected ERS
– error seconds; number of seconds during which errors occurred
11)
Status
– BER tester synchronization status (sync|nosync) or n/a when there is no
active link to the remote side or free capacity left for the BER tester