Phoenix G2 IDU User Manual OVERVIEW
SAF Tehnika JSC
14
Layer 1Link bonding is supported as aggregation technique
Figure 1.13
PhoeniX G2 2+0/2+0 XPIC configurations
PhoeniX G2 2+2 FD/2+2 XPIC configurations:
2+2 FD configuration is used to aggregate payload traffic (capacity doubling)
using 2 frequency pairs. HSB/SD and FD protection is provided for the
aggregated links.
2+2 XPIC configuration is used to aggregate payload traffic using 1 frequency
channel in both polarizations Vertical and Horizontal simultaneously. HSB/SD
and FD protection is provided for the aggregated links.
Layer 1Link bonding is supported as aggregation technique
Figure 1.14
PhoeniX G2 2+2 FD/2+2 XPIC configurations
Both IDUs in each side of the link are interconnected with 2 optical cables on ports SFP1 and
SFP2. 2.5 GB SFP modules must be used for this interconnection. SFP3 or SFP4 ports can
be used for the IDU interconnection with EMM modules.
EMM extension modules description
ASI EMM extension module
The ASI EMM extension module provides ASI interface extension for Phoenix G2 IDUs. The ASI
EMM module multiplexes up to 4 ASI channels into the compact stream which is directed over