Note 1: At 80 MHz and 800 MHz, the higher frequency range applies.
Note 2: These specifications may not be applicable in all situations. Electromagnetic propagation is affected by
absorption and reflection from structures, objects and persons.
(a): The electromagnetic field strength of fixed radiofrequency emitters, such as base stations for mobile telephones
(cellular / cordless), mobile radio, AM/FM radio broadcasts and TV broadcasts cannot be determined exactly by theory.
To assess the electromagnetic environment due to fixed radiofrequency emitters, an electromagnetic environment
measurement must be made. If the measured radiofrequency field strength in the immediate environment where the
product is used exceeds the compliance level specified above, the performance of the product must be tested to verify
whether it conforms to the specification. If abnormal performance is observed, additional measures may be necessary,
such as reorienting or relocating the product.
(b): In the 150 kHz to 80 MHz frequency range, the electromagnetic field strengths must be less than 3V/m.
(3) ELECTROMAGNETIC IMMUNITY / RADIOFREQUENCY MOBILE EQUIPMENT
Emission test
Conducted RF
IEC 61000-4-6
EN 61000-4-6
3Vrms
150kHz to 80Mhz
3Vrms
Portable and mobile RF communications
equipment should be used no closer to any
part of the TRAUS SIP10 including cables,
than the recommended separation distance
calculated from the equation applicable to the
frequency of the transmitter.
Recommended separation distance
d = 1.2 √P
d = 1.2 √P 80MHz to 800MHz
d = 2.3 √P 800MHz to 2.5GHz
Where ‘P’ is the maximum output power rating
of the transmitter in watt (W) according to the
transmitter manufacturer
‘d’ is the recommended separation distance (m).
The electromagnetic field strength of fixed
radiofrequency emitters, which is determined
by an electromagnetic environment
measurement (a), must be less than the
compliance level in each frequency range (b).
Interference may occur near equipment
marked with the symbol below:
3V/m
3V/m
80MHz to 2.5GHz
Radiated RF
IEC 61000-4-3
EN 61000-4-3
IEC 60601 test level
Compliance level
Electromagnetic environment – guidance
Cables and
accessories
Micro motor with
motor cord
1.7M
Unshielded
RF emissions, CISPR11 Class A / Group 1
IEC 61000-3-2
EN 61000-3-2
IEC 61000-3-3
EN 61000-3-3
IEC 61000-4-2
EN 610000-4-2
IEC 61000-4-4
EN 61000-4-4
IEC 61000-4-5
EN 61000-4-5
IEC 61000-4-11
EN 61000-4-11
IEC 61000-4-8
EN 61000-4-8
IEC 61000-4-6
EN 61000-4-6
IEC 61000-4-3
EN 61000-4-3
Harmonic emissions
Voltage fluctuations /
flicker emissions
Electrostatic discharge
(ESD)
Electrical fast transient /
burst
Surge
Voltage dips, short
interruptions and voltage
variations on power
supply input lines
Power frequency
(50/60Hz) magnetic field
Conducted RF
Radiated RF
Unshielded
Unshielded
1.7M
1.7M
Foot controller with
cord
AC power cord
Maximum length
Shield
Complies with
38