background image

 

 

 

BACK-LEG-CHEST DYNAMOMETER(SH5007) 

User Manual 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание SH5007

Страница 1: ...BACK LEG CHEST DYNAMOMETER SH5007 User Manual...

Страница 2: ...liance should be checked for correct condition prior to each usage by a person familiar with proper operation of the balance INFORMATION ON COMPONENTS PACKAGE CONTENT No Name Function 1 Body All metal...

Страница 3: ...device in areas of high temperature especially in places near heating equipment in moist or dusty places or where it will be directly exposed to water If the device is dirty wipe it with a soft dry cl...

Страница 4: ...dy This insures that it does not interfere with the movement of the Pointer during the trial 1 Arm Lift 2 Torso Lift 3 Leg Lift 4 High Far Lift 5 Floor Lift 6 High Near Lift 3 Have the subject hold th...

Страница 5: ......

Страница 6: ...it s design are not permitted This may lead to incorrect measuring results safety related faults and destruction of the device The device may only be operated in accordance with the described default...

Страница 7: ...y rooms doctors offices and patients rooms etc Equipment can be damaged when dropped to the floor Impossible to expect to work properly any more If it works properly calibration exactitude should be m...

Страница 8: ...f the location where the appliance is used Warranty Warranty claims shall be voided in case Our conditions in the operation manual are ignored The appliance is used outside the described uses The appl...

Страница 9: ...de Catalogue number Caution Fragile handle with care Keep dry Keep away from sunlight Consult instructions for use If there has been occurred any serious accident in relation to the our device release...

Страница 10: ...amgongdan 13 gil Masanhoewon gu Changwon 51342 South Korea Phone 82 55 294 0381 Fax 82 55 293 5019 E mail saehancorp naver com Website www saehanmedical com MVS In Motion Westdijk 150 2830 Tisselt Bel...

Отзывы: