AULIKA 05 FAULT FINDING
Rev. 00 / July 2012
Page / 08
5.3. Error messages
code
brief description
description
01
coffee grinder blocked
the coffee grinder is blocked (the burrs are stuck or
the sensor does not read accurately)
03
brewing unit blocked in "work"
mode
the descent time out has been exceeded
04
brewing unit blocked in "home"
mode
the ascent time out has been exceeded
05
water circuit interrupted
no water flows into the turbine
06
emulsifier unit solenoid valve
short circuit of a solenoid valve in the emulsifier unit
07
doser microswitch blocked
short circuit of the doser microswitch
10
coffee boiler short-circuited
short-circuit in the temperature sensor of the coffee
boiler
11
coffee boiler open circuit
open circuit in the temperature sensor of the coffee
boiler
12
steam boiler short-circuited
short-circuit in the temperature sensor of the steam
boiler
13
steam boiler open circuit
open circuit in the temperature sensor of the steam
boiler
14
various temperature errors
(of the coffee boiler)
coffee boiler temperature out of control
15
various temperature errors
(of the steam boiler)
steam boiler temperature out of control
16
brewing unit short-circuited
short circuit of the brewing unit microswitch
17
not used
18
not used
19
zero crossing fault
no zero crossing on the card, the cause might derive
from the power card
20
not used
08
Содержание Aulika SUP040R
Страница 3: ...Rev 00 July 2012 AULIKA...
Страница 8: ...Rev 00 July 2012 AULIKA...
Страница 13: ...Rev 00 July 2012 AULIKA...
Страница 21: ...Rev 00 July 2012 AULIKA...
Страница 29: ...Rev 00 July 2012 AULIKA...
Страница 38: ...Rev 00 July 2012 AULIKA...
Страница 41: ...Rev 00 July 2012 AULIKA...
Страница 51: ...Rev 00 July 2012 AULIKA...
Страница 52: ...AULIKA 08 NOTES Rev 00 July 2012 Page 01 01...
Страница 53: ...Rev 00 July 2012 AULIKA...
Страница 54: ...AULIKA 09 HYDRAULIC DIAGRAM Rev 00 July 2012 Page 01 01...
Страница 55: ...Rev 00 July 2012 AULIKA...
Страница 56: ...AULIKA 10 ELECTRIC DIAGRAM Rev 00 July 2012 Page 01 01...