![SABROE SAB 283 Скачать руководство пользователя страница 66](http://html1.mh-extra.com/html/sabroe/sab-283/sab-283_operation-manual_3168701066.webp)
Table 23: Compressor block
Symptom
Probable cause
Solution
Oil pressure is not sufficient
Check oil pressure
Solenoid coils may be burned
out
Replace
Incorrect setting of valves in
the hydraulic system
Check according to hydraulic
system description
Capacity slide valve and/or
slide stop will not move. Cannot
unload or load, or both
Malfunction of four-way control
valve of slide components
Check according to description
of main components
Demand oil pump system, optional
Table 24: Demand oil pump system, optional
Symptom
Probable cause
Solution
Pump rotation
Check the pump rotation
Service valves closed
Open valve
Filter cartridges may be
blocked
Check pressure difference
across filters
Strainer may be blocked
Clean strainer
Oil pressure regulator set too
low or stuck open
Re-adjust or repair
Pump worn out
Repair or replace
Pump will not produce
enough oil pressure to start
compressor
Hand expansion valve (position
124) may be open too much
Throttle the valve
Oil pressure rapidly drops
off when compressor starts.
Results in compressor
differential alarm
Main oil injection throttling
valve open too wide or oil
pressure regulating valve
improperly adjusted
Re-adjust both valves
Oil pressure fluctuates
Liquid injection overfeeding
or refrigerant flood back from
system
Make necessary adjustments or
corrections
Pump strainer blocked
Clean the strainer
Liquid refrigerant overfeed
Adjust the liquid injection
Noise and vibrations
Pump worn out
Repair or replace
Grease leaks from vent port in
the side of the pump body
Normal leakage which will
cease after initial operation.
Black oil leaking from this vent
indicates oil seal wear or failure
If leakage exceeds the normal
allowable rate of 7 drops per
minute, replace the seal
Filters clogged with dirt
Replace the filters
Oil is too cold
Allow the oil to warm up
Main filter pressure difference
is too high
Service valve on filter outlet is
partially closed
Open valves fully
SAB 283-355 A-Frame OHU 6042 and OHU 7650 (including ATEX) Screw Compressor Unit
66