background image

6.4.6

 

Admin Cell Numbers 

 

 

The GSM GENIE can be programmed with up to 10 admin cell phone numbers. These 10 numbers will be 
able to control the unit by SMS. 

Please note: 

Only the “Master Number” will receive the daily test 

report as described in section 6.2.5. 

HINT: Always make sure that the “Master Number” is programmed.

 

 

 

 

Содержание GSM GENIE

Страница 1: ...User Manual Revision 1 02 Manufactured by ...

Страница 2: ...Info 12 6 4 General Settings 13 6 4 1 General 13 6 4 2 Missed Call Control 13 6 4 3 Arm Disarm Control 13 6 4 4 AC Detect 14 6 4 5 Daily Test Report 14 6 4 6 Admin Cell Numbers 15 6 4 7 Gate Control Settings 16 6 5 Inputs Outputs 17 6 5 1 Digital Inputs 17 6 5 2 Analog Inputs 18 6 5 3 Digital Outputs 19 6 6 SMS Messages 20 6 6 1 Admin SMS Commands 20 6 6 2 Gate Control SMS Commands 21 6 7 Logs 21 ...

Страница 3: ...7 ioXpander Add On Board 23 7 1 Specifications 23 7 2 Adding a ioXpander board to your profile 24 7 3 4 20mA Inputs 24 ...

Страница 4: ...he product has been manufactured to the best standards and strictly in line with the design specifications however the manufacturer supplier and all other parties cannot guarantee it will function in one hundred percent of applications and circumstances The system is reliant on third party service providers and Sabertek and its partners have no control over these third parties For this reason we r...

Страница 5: ...C Battery charging will be suspended above 50 o C Digital Inputs 0 12V Isolated Analog Inputs 0 30V Relay Outputs 3A 125VAC 30VDC AC Input 0 400VAC Lead Acid Battery 12V IO Connector Type Pluggable screw terminals 4 Features Digital Inputs 2 Analog Inputs 2 Digital Outputs 2 AC inputs 1 Lead Acid Battery YES Internal Battery YES SIM Card Slot 1 GPRS Capability YES RF Interface Coming soon ...

Страница 6: ...art flashing If not make sure the power supply is plugged in and switched on 5 The unit will now try to connect to the server for the first time If successful the heartbeat LED will start blinking with a double flash It should not take longer than 5 minutes Please Note If the red GSM LED does not stop flashing after a short while make sure the GSM antenna is connected and the SIM card in inserted ...

Страница 7: ... Please note that you will not be able to use this software without an internet connection 2 Start the software by double clicking on the EXE file downloaded in step 1 The login screen should be visible 3 First time users will first have to register by clicking on the Register button ...

Страница 8: ...You should now be logged into the software 6 If the unit has made a successful connection as described in section 5 1 it can be added to your profile Several GENIE s can be added to a single profile 7 To add the GENIE to your profile click the Add MainBoard button and enter the unit s serial number in the textbox 8 Click the Add board button The software will return to the main screen and the newl...

Страница 9: ...o fetch new settings from the cloud server This can be immediately requested by sending a SMS to the unit refer to section 6 6 BUT your cellphone number must be in the Authorized Cell Numbers section under the General Settings tab 11 When finished with configuring the unit click the Send Settings button This will upload all settings to the cloud server ...

Страница 10: ... 2 Events The GSM GENIE is an event based system where certain inputs can trigger events Events can be anything from switching an output or sending a SMS message The GSM GENIE cater for 64 different events 6 2 1 Configuring Events Events are configured using the Manage Events button on the main screen Event Name Name of the event It is advisable to give a descriptive name to each event because it ...

Страница 11: ... 6 2 1 3 CALL Event This event will generate a missed call to a specific cell phone number The number can be entered in the available text box 6 2 1 4 DSP Event This event will display a message on a DSP Xpander board The desired DSP board can be selected via the dropdown which will automatically be populated with the available DSP boards The DSP board have 5 different modes which will be explaine...

Страница 12: ...GSM modem IMSI International Mobile Subscriber Identity IMSI of the unit s SIM card Cell Number Cellphone number of the unit s SIM card Signal Quality CSQ GSM signal quality of the unit A value above 15 is preferred to ensure good communication between the unit and cloud server Last Seen The timestamp of the last connection between the unit and cloud server Updated Indicates if the unit has receiv...

Страница 13: ... message for security purposes This password is used to perform all SMS functions SIM Pin The 4 digit pin code of the SIM card Please note If this pin code does not correspond to the pin code of the SIM card you GSM GENIE will not be able to communicate 6 4 2 Missed Call Control When enabled the GSM GENIE will respond to missed calls from any authorized number refer to section 6 4 6 When disabled ...

Страница 14: ...6 4 4 AC Detect This is a dedicated input for AC mains to detect power outages The trigger time in minutes is the time that needs to elapse before the unit will trigger the OFF ON events 6 4 5 Daily Test Report When enabled the unit will send a daily SMS report to the Master Number refer to section 6 4 6 This gives the user confirmation that the unit is in working order and have network coverage T...

Страница 15: ...d with up to 10 admin cell phone numbers These 10 numbers will be able to control the unit by SMS Please note Only the Master Number will receive the daily test report as described in section 6 2 5 HINT Always make sure that the Master Number is programmed ...

Страница 16: ...efore a temporary cell number expires Two Gate Setup If the complex or estate have separate gates for entry exit this feature must be enabled SMS Msg The SMS message that must be sent to execute the selected events Gate Control Nrs can use Missed Call If enabled temporary cell numbers will be able to missed call the unit See section 6 4 2 Gate Control Cell Numbers The GSM GENIE can be programmed w...

Страница 17: ...annel Name The name for the channel Trigger Time When an input changes state this is the time in milliseconds that have to elapse before the input will trigger any event The trigger time will reset if the input change state during this time Debounce Time This the time in milliseconds that have to elapse after a state change before the input will trigger again Please Note Each digital input have a ...

Страница 18: ... events Trigger Time When an input changes state this is the time in milliseconds that have to elapse before the input will trigger any event The trigger time will reset if the input change state during this time Debounce Time This the time in milliseconds that have to elapse after a state change before the input will trigger again Log Interval If enabled the actual value of the analog input toget...

Страница 19: ...minals will be internally connected to each other Please Note Each output have a LED indicator which will be ON when the output is ON Channel Name The name for the channel Pulse Length The time in milliseconds that the output will change state when pulsed Pulse Count The amount of pulses that will be generated if the output is triggered Default State The default state of the output Schedule takes ...

Страница 20: ...s 6 6 1 Admin SMS Commands Only admin cell numbers will be allowed to use this functionality Gate control numbers will not be allowed SMS Format All SMS messages must be prefixed with the password chosen in section 6 4 1 and type of message After the password type the SMS instruction must follow Please note The instruction part of the message is not case sensitive Query Command SMS Command Descrip...

Страница 21: ...e unit will reply with its prepaid airtime balance Please note This will not work correctly with a contract SIM card or when roaming 6 6 2 Gate Control SMS Commands This SMS messages do not need to be prefixed with the password Please Note Admin Numbers can also use this functionality SMS Command Description TA x Allow temporary access to a cell number Example TA 0821234567 The unit will automatic...

Страница 22: ...s Please note Settings must first be uploaded to take effect If you like to undo please click on Download Settings without uploading the settings 6 8 2 Copy Paste Settings Settings can be copied between boards of the same type To copy settings from one board to another right click on Copy Settings then right click on the new board and select Paste Settings ...

Страница 23: ...ifications Dimensions mm 110x90x27 WxHxD Power Supply 9 32V DC via DC Jack Operating Current 60mA no loads connected Power Consumption 2W Operating Temperature 10 to 65o C Digital Inputs 4x 0 12V Isolated 4 20ma Inputs 4x 0 30V Relay Outputs 6x 3A 125VAC 30VDC IO Connector Type Pluggable screw terminals Please note This unit will not be able to operate without a GSM Genie mainboard ...

Страница 24: ...ase note All changes to your current settings will be discarded if not uploaded 3 If successful the newly added IOX board will be visible under the Xpanders section 4 Click on the board to open the configuration page on the left 5 For Digital Input settings refer to section 6 5 1 6 For Digital Output settings refer to section 6 5 3 7 The 4 20mA inputs will be explained in the next section 7 3 4 20...

Страница 25: ... minimum reading this will normally be where the sensor outputs 4mA Sensor Max The sensors maximum reading this will normally be where the sensor outputs 20mA Log Interval If enabled the actual value of the analog input together with the time will be logged The interval options shown in the picture below Values can be exported by clicking on Show Log for analyses Please note For detailed configura...