Saadat BP4 Скачать руководство пользователя страница 6

 

III

 

General Warnings  

 

Warning  

 

Do not use the cuff or AC adapter to lift the unit, it can also cause the unit to malfunction. 

 

If the unit has broken down, contact your local representative. 

 

Do not use in combination with a hyperbaric oxygen therapy device, or in an environment 
where combustible gas may be generated. 

 

Do not use in combination with magnetic resonance imaging (MRI) equipment. If MRI is to 
be performed, remove cuff connected to the unit from the patient. 

 

Do not use with a defibrillator. 

 

Do not install the unit in the following locations: 

o

 

Locations  subject  to  vibration  or  shock  such  as  ambulances  and  emergency 
helicopters. 

o

 

A location where there is gas, flame or heater. 

o

 

A location where there is water or steam. 

o

 

A location where chemicals are stored. 

o

 

Locations with dust, salt or sulfur.  

o

 

Locations directly exposed to sunlight for extended period of time. In particular, do 
not leave in direct sunlight or near a source of ultraviolet (UV) for extended periods, 
as UV will cause deterioration of the LCD.  

 

Do not use at extremely high temperature, high humidity, or high altitude. Use only within 
the required ambient conditions. 

 

Do not use this unit in the presence of flammable gas or in a high-pressure oxygen room or 
oxygen extent. 

 

Do not use an AC adapter or battery pack not specified for this unit 

 

Do not place heavy objects on the AC adapter cable, or allow the unit to sit on the cord. 

 

Do not use a broken power cord or AC adapter. 

 

Do not plug in or unplug the AC adapter with wet hands. 

 

Do not use the battery pack of other devices for this unit. 

 

Do not disassemble the battery pack. 

 

Unplug the AC adaptor from the electric outlet if this unit is unused for an extended period 
of time. 

 

Unplug the AC adaptor from the electric outlet when installing, removing or cleaning the 
unit. 

 

Do not share an electric outlet with another unit or electric appliance. 

 

After  cleaning  this  unit,  dry  it  well  before  plugging  the  AC  adapter  in  the 
electric

 

outlet

.

 

 

If  this  unit  fails  to  perform  as  indicated,  discontinue  use,  turn  off  the  unit, 
unplug  the  AC  adapter  from  the  electric  outlet,  and  contact  company’s  repair 
department

.

 

 

Do not disassemble or modify this unit. 

 

Do not use any cuff other than the models exclusive for this unit. 

 

Do not use this unit on infants. 

 

Do not use this unit in a vehicle. 

 

Use only authorized parts and accessories. Parts and accessories not approved for use with 
the device may damage the unit 

 

If the device is equipped with rechargeable  batteries, do not attempt to replace them. It is 
built-in and not changeable.  

 

If you have any problems with this device, such as setting up, malfunction, maintaining or 
using, contact with customer service for assistance.  

Содержание BP4

Страница 1: ...User Manual Digital Blood Pressure Monitor Model BP4 D01027 V1 Software version 220 1 x x POOYANDEGAN RAH SAADAT Co...

Страница 2: ...21 77960719 98 21 77962181 Fax 98 21 77964239 Customer Services Tel 98 21 73098000 98 21 77798910 Cell 98 912 1977157 Fax 98 21 77960761 Legal responsible Trionara Technologies AB Polygonv gen 21 1876...

Страница 3: ...8 Installation of Batteries for devices which have no built in rechargeable batteries 8 Installation of rechargeable lithium Batteries 8 Using the AC Adapter 8 Symbols of Display 10 Chapter 2 System...

Страница 4: ...the used expressions in this manual Version Information This manual has a version number The version number changes whenever the manual is updated due to technical specification changes The version in...

Страница 5: ...r manual of the device and pay attention to the warnings and cautions This symbol indicates that the equipment shall be disposed of in an environmentally friendly manner Direct current CE mark Serial...

Страница 6: ...xtent Do not use an AC adapter or battery pack not specified for this unit Do not place heavy objects on the AC adapter cable or allow the unit to sit on the cord Do not use a broken power cord or AC...

Страница 7: ...ous cuff pressure due to connection tubing kinking may cause blood flow interference and result in harmful injury to the patient NIBP reading can be affected by the measurement site the position of th...

Страница 8: ...nd physiological precision in measurements The device estimates the systolic blood pressure during inflation and inflates to a proper cuff pressure approximately 30 40 mmHg above the patient s systoli...

Страница 9: ...ted and the results showed a reliable measurement of the NIBP module in theses patient The performance of NIBP module in pregnant women was evaluated and the results showed a reliable measurement of t...

Страница 10: ...tor Front of the monitor a Display b Next Increase c Mode d Previous Decrease e Charging LED f START STOP button Left side right side and bottom of the monitor g AC adapter jack left side h Battery co...

Страница 11: ...connector and replace with a new one 3 Install the battery cover and fasten it with both screws Be careful not to pinch the lead wire 4 Connect the main unit to the AC adapter to charge the new batte...

Страница 12: ...n where it is difficult to plug and unplug the AC adapter We recommend keeping batteries in your monitor at all times even if you choose to use the AC adapter If only the AC adapter is used without ke...

Страница 13: ...itchable Systolic pressure Diastolic pressure Error number Heartbeat Measurement unit Measurement unit Bluetooth indicator Memory indicator Record number Appear when viewing stored readings Time Date...

Страница 14: ...he month number setting mode The month number is displayed as a blink and changes by pressing the up or down keys By pressing the key again the day number setting mode is activated The day number is d...

Страница 15: ...ff is used the measured blood pressure value tends to be lower than the actual blood pressure If too small a cuff is used the measured blood pressure value tends to be higher Before and during measure...

Страница 16: ...e correct arm position and is at the same height as the heart Start measurement 1 Press the START STOP button once to switch on the device 2 Attach the cuff to your arm see Attaching the cuff and make...

Страница 17: ...e used for disinfection Note Take extra care when cleaning the screen of the monitor because it is more sensitive to rough cleaning methods than the housing Don t spray a liquid directly on the screen...

Страница 18: ...Measuring pressure is more than upper limit 255mmHg for adult Repeat measurement If the error is displayed again use another method to measure the patient s blood pressure 11 EXCESSIVE MOTION Arm move...

Страница 19: ...uracy 2 or 2 BPM whichever is greater Initial cuff pressure 160 mmHg Safety Regulatory Standards IEC 60601 1 EN 60601 1 2 EN 60601 1 11 IEC 80601 2 30 ISO 81060 2 ISO 10993 5 ISO 10993 10 NIBP Accurac...

Страница 20: ...Appendix 1 Accessories 17 Appendix 1 Accessories PART Number NIBP Accessory P48028 NIBP Reusable Cuff Adult Single M5134 Tube Length 50 cm Limb Circumference 25 35cm...

Страница 21: ...t In case adjacent or stacked use is necessary the medical device should be observed to verify normal operation in the configuration in which it will be used During use or measurement portable RF comm...

Страница 22: ...should be at least 30 8 kV contact 2 kV 4 kV 8 kV 15 kV air N A Enclosure Electrostatic discharge ESD IEC 61000 4 2 Patient coupling Signal I O parts N A Input a c power Electrical fast transient bur...

Страница 23: ...patient monitor should assure that it is used in such an environment Electromagnetic Environment Guidance Compliance Level Port Immunity Test N A Input a c power Conducted RF IEC 61000 4 6 Patient cou...

Страница 24: ...Hz GSM 800 900 TETRA 800 iDEN 820 CDMA 850 LTE Band 5 800 960 810 870 930 28 0 3 2 Pulse modulation b 217 Hz GSM 1800 CDMA 1900 DECT LTE Band 1 3 4 25 UMTS 1700 1990 1720 1845 1970 28 0 3 2 Pulse modu...

Страница 25: ......

Отзывы: