background image

 6

3 Technical data 

3.1 Installation drawing 

A

. Drain outlet/hose connection 

B

. Pressure gauge

3.1 Installation drawing – Wall Mount

A

. Inlet 

B

. Drain outlet/hose connection 

C

. Pressure gauge

 5

65 m

m

 /

 2

2,

3"

 

 1340 mm / 52,8" 

1/2

Checked By

and

it

 is

to be r

eturned prom

tly upon

reques

t t

o G

RAN

ULD

IS

K A

B.

Thi

s

drawi

ng

contai

ns

 c

on

fi

denti

al i

nf

or

mat

ion

and

is

 t

he property

of 

GR

A

NU

LD

IS

K

A

B w

hi

thout 

whos

e perm

is

si

on i

t m

ay not 

be

2021-10-19

Date

A2

Checked Date

1:10

0

Edition

Designed by

Scale

Drawing number

Filter_Install

Sheet

copi

ed,

sh

ow

n or 

han

ded t

o

a t

hi

rd part

y or 

otherw

is

e us

ed

,

GIS number

A2

Status

Projection method

Additional Information

O

ut

let

, d

ep

en

d

on

 se

ttin

g

 o

f m

a

ch

in

e f

eet

 1

670 m

m

 /

 65,

8"

 

Decon washer max

 955 mm / 37,6" 

 6

25 m

m

 /

 2

4,

6"

 

Fr

ee

 sp

a

ce f

or

 fi

lter

 ex

ch

a

ng

e

 6

95 -

 1715

 m

m

27,

4"

 - 67,

5"

A2

Projection method

Checked Date

Checked By

Scale

Date

Thi

s

drawi

ng

contai

ns

 c

on

fi

denti

al i

nf

or

mat

ion

and

is

 t

he property

and

it

 is

to be r

eturned prom

tly upon

reques

t t

o G

RAN

ULD

IS

K A

B.

of 

GR

A

NU

LD

IS

K

A

B w

hi

thout 

whos

e perm

is

si

on i

t m

ay not 

be

Filter_Install

2021-10-19

1:10

0

Edition

Designed by

Status

Drawing number

copi

ed,

sh

ow

n or 

han

ded t

o

a t

hi

rd part

y or 

otherw

is

e us

ed

,

Sheet

2/2

GIS number

A2

Additional Information

Mounting of wall bracket

- Floor Level -

 180 mm / 7" 

 180 mm / 7" 

 180 mm / 7" 

 4x  8 m

m / 0,32" 

650 -

 1670 m

m

No

t lo

w

er

 th

a

d

ra

in

 690 mm / 27,2" 

Inl

et

 (D

ep

. o

n m

ou

nt

ing

 he

ig

ht

)

O

ut

le

t (

D

ep

. o

m

ou

nt

ing

 he

ig

ht

)

25,

6"

 - 65,

8"

650 -

 1670 m

m

25,

6"

 - 65,

8"

 6

25 m

m

 /

 2

4,

6"

 

Fr

ee

 sp

a

ce f

or

 fi

lter

 ex

ch

a

ng

e

C

B

A

A

B

Содержание RESCUE Intellitech DeconFilter Pro S

Страница 1: ...Installation user instructions and service DeconFilter Pro S Manual ...

Страница 2: ... 3 1 Installation drawing Wall Mount 6 4 Installation 7 4 1 Mounting the filter rack 7 4 2 Pressure gauge 9 4 3 Tank installation 9 4 4 Filter cartridge installation 13 5 Operation 13 6 Service Maintenence 14 6 1 Filter change interval 14 6 2 Replacement Cartridges 15 6 3 Replacement of Filter Cartridges 15 6 4 Cleaning 15 7 Spare parts list 17 ...

Страница 3: ...ystem is powered off by disconnecting the DeconFilter Pro S from the electrical socket all use of the connected Solo Rescue Decon Washers is prohibited 2 3 Limited Warranty RESCUE Intellitech warrants and represents that all of its products are free of defects in materials or workmanship for a period of twelve 12 months from the date of delivery subject to normal wear and tear and provided that th...

Страница 4: ...of or related to this agreement whether arising out of or related to breach of contract tort including negligence or otherwise shall not exceed the total amount paid under this agreement during the 12 month period preceding the event giving rise to the claim The limitations of liability set out herein shall not apply with respect to damages arising out of grossly negligent acts or omissions or wil...

Страница 5: ... GIS number A2 Status Projection method Additional Information Outlet depends on setting of machine feet 1670 mm 65 8 Decon washer max 955 mm 37 6 625 mm 24 6 Free space for filter exchange 695 1715 mm 27 4 67 5 Projection method Checked Date Checked By Scale ains confidential information and is the property urned promtly upon request to GRANULDISK AB B whithout whose permission it may not be 1 10...

Страница 6: ...1 1 Mounted on the Solo Rescue NOTE Not applicable for Solo Rescue 32 series use wall mount accessory instead See section 4 1 2 1 Unscrew the bolt holding the top cover on the right side of the Solo Rescue Fig 1 2 Position the filter rack pins in the holes as displayed in Fig 2 3 Fasten the previously unscrewed bolt to fix the filter rack on the Solo Rescue Fig 3 Figure 1 Figure 2 Figure 3 ...

Страница 7: ...tely 30 kg 66 Ibs 1 Remove the filter rack securing bolts Fig 4 2 Make sure the wall mount is level If drilling is needed make sure to mark where as displayed in Fig 5 3 Fasten the wall mount on the wall using four screws in the holes as displayed in Fig 5 3 Position the filter rack pins in the holes Fig 6 4 Fasten the previously unscrewed rack securing bolts to fix the filter rack on the wall mou...

Страница 8: ... rubber cap on the top Fig 8 9 Figure 8 Figure 9 4 3 Tank installation 1 On the right hand side of the Solo Resce loosen the nuts on the levelling feet and position the tank Fixate it by tightening the nuts again Fig 10 2 Make sure the tank is in level by adjusting its feet Fig 11 Continues on next page Figure 10 Figure 11 ...

Страница 9: ...e tank feet Fig 12 4 Connect the included drain pipe connections between the Solo Rescue drain outlet and the tank inlet Fig 13 5 Place the provided submersible pump in the tank and make sure the arrows on the anti rotation plate points to the front of the tank Fig 14 Continues on next page ...

Страница 10: ...et to filter inlet at filter housing 1 Fig 15 16 7 Connect the hose to the pump outlet and secure it with one of the provided hose clamps Fig 15 8 Pull the hose through the cable gland and secure it to the tank using the locknut Fig 17 9 Secure the power cable with the rubber grommet Fig 17 18 Continues on next page ...

Страница 11: ...the provided hose clamps Fig 20 12 Connect the other end of the hose to the drain floor drain according to local regulations Figure 19 Figure 20 Figure 21 IMPORTANT NOTES Never use a drain hose longer than 6 m 18 ft Height of wall mounted drain outlet must never exceed 1 5 m 5 ft from the floor Avoid sharp bends or blocking s as it may limit the output flow and cause a raised pressure in the syste...

Страница 12: ...ter socket of the 2 filter housing head Mount the sump with the clamp and tighten it by hand NOTE Filter break in it takes a couple of water changes from the Solo Rescue before the new filter cartridges reaches their full filtering performance 5 Operation The DeconFilter Pro S is designed and built to be connected at all time and it operates without human interaction It is advised to frequently ke...

Страница 13: ...system is powered off by disconnecting the DeconFilter Pro S from the electrical socket it is strongly recommended to clean the tank and pump inlet all use of the connected Solo Rescue Decon Washers is prohibited 6 1 Filter change interval Every three months or according to pressure indicator More often depending on application 6 1 1 Service Indicator Monitor the System Pressure gauge Fig 23 on th...

Страница 14: ...the tank 4 Unscrew the filter sumps and dispose the filter cartridges according to local regulations for hazardous materials CAUTION Scalding risk hot water 5 Clean the insides of the filter sumps and install new filter cartridges according to section 4 4 Filter cartridge installation 6 Connect the power to the submersible pump 6 4 Cleaning 6 4 Cleaning the tank 1 Make sure the tank is empty 2 Dis...

Страница 15: ...s 2 Clean and rinse the intake cage impeller and the impeller cover with clean water Fig 26 27 CAUTION Do not rest the pump on the impeller 3 Reassemble the impeller cover and push the intake cage back in place 4 Install pump and lint filter by reversing the disassembly steps NOTE There are no parts inside the pump housing which require additional maintenance Figure 26 Figure 27 ...

Страница 16: ...on Part Number 1 Pump complete 90041 2 Manometer 28078 3 Filter housing 1 complete 90042 4 Filter housing 2 complete 90043 5 Filter housing 3 complete 90044 6 Pump restrictor 27454 7 Lint filter 27128 8 O ring kit for Filter Housing 1 3 90051 1 7 8 2 3 6 5 4 ...

Страница 17: ...r mission to help protect them Reducing the amount of toxic chemicals and carcinogens that firefighters are exposed to on a daily basis is one of several critical aspects of ensuring a safe work environment and firefighters long term health With the Solo Rescue Decon Washer your fire department can reduce toxic chemicals and carcinogens in a quick easy and safe way By adding our DeconFilter Pro S ...

Отзывы: