EZ Hauler 4100 Control Valve Troubleshooting Guide
Theory of Operation
– The control valve for the EZ Hauler 4100 includes three sections:
1
Mid-inlet section
2
To the right of the mid-inlet section:
1. Five 4-GPM four-way, three-position valve sections.
2. These five valve sections control Boom Lift, Boom Extend, Winch, Auxiliary, and Rotation
3
To the left of the mid-inlet section:
1. One 13-GPM four-way three-position valve section
2. This section controls the Auger function
To the left of the Auger Section is an end section containing an inlet gage port (MP), a pilot
pressure gage port (PPG) and two mounting holes. All valve sections are individually pressure
compensated. The 4 GPM sections use a screw in cartridge pressure compensator set at 290
PSI. The 13 GPM section uses a slip-in compensator that is also set at 290 PSI. All valve
sections are electro-hydraulically operated with a lever type manual override. Each electro-
hydraulic valve actuator uses two proportional flow control valves along with a Hall Effect
position transducer and onboard electronics to precisely control spool position. The input signal
is a voltage signal with neutral at 2.5 volts. The mid inlet contains a bypass compensator (CP3),
a load sense orifice, a compensator decompression orifice, a pilot relief valve (VS) that controls
the inlet compensator, a pressure reducing valve (RPM) set at 290 PSI to supply pressure to the
proportional flow control valves and a control disable solenoid valve (EV9) that interrupts
pressure to the proportional valves. The bypass compensator is controlled by the individual
valve sections through a load sense shuttle logic. A cartridge shuttle is located in each valve
section.
Control Requirements
- Each electro-hydraulic valve actuator has a four-pin connector. Pin call-
outs are included in the following chart.
PIN NUMBER
DESIGNATION
COMMENT
1
Power
9 to 30 volts with E-stop enabled. 0 volts with E-stop
disabled.
2 Ground
3
Signal
Neutral - 2.5 +/- 0.1 Volts
Maximum Stroke A - 4.1 Volts (DO NOT exceed 4.75
Volts)
Maximum Stroke B - 0.9 Volts (DO NOT drop below
0.25 Volts)
4
5 Volts Out
Not used
Содержание EZ Hauler 4100
Страница 2: ......
Страница 6: ......
Страница 10: ......
Страница 13: ...Chapter 2 Specifications 11 Geometric Configuration 28 10 5 11 41 4 4 3 4 5 8 35 7 34 4 ...
Страница 27: ...Chapter 3 Parts 25 Valvebank 70733995 Drawing not available at time of printing ...
Страница 30: ...28 EZ Hauler 4100 Manual Part 99903718 Boom Assemblies Cylinders BoomAssembly 99903706 ...
Страница 39: ...Chapter 3 Parts 37 Boom TipAsembly 51719583 3 11 7 9 2 5 6 16 14 8 10 13 15 2 PLCS 12 2 PLCS 4 ...
Страница 44: ...42 EZ Hauler 4100 Manual Part 99903718 Hydraulics Hydraulic Layout 99903715 ...
Страница 47: ...Chapter 3 Parts 45 Hydraulic Schematic 99903702 ...
Страница 61: ...Chapter 3 Parts 59 Wiring Schematic Radio Remote 99903721 2 ...
Страница 66: ......
Страница 75: ...Chapter 4 Crane Reference 73 X R CA ITEM EXPLANATION DATE CORRECTED ...