INSTALLATION—HEAD ASSEMBLY

4.

Check that the side columns are plumb and square 
with the floor and wall.

5.

Tighten all anchor hardware securing both side col-
umns to the wall.

6.

Remove any bar clamps that may have been used 
to temporarily hold the side columns to the wall.

HEAD ASSEMBLY

1.

Before removing the head/fabric roll assembly from 
the shipping crate, locate four 

¹₂

-13 x 1

¹₄

-in. ser-

rated-flange hex screws, four 

¹₂

-13 serrated-flange 

nuts, and the flange bearing assembly in the small 
parts carton.

NOTE:

The 

¹₂

-13 x 6-in. hex screws that were

installed earlier will be used to attach the
head assembly to the side columns.

Also, some oversized doors require a
steel spacer between both side columns
and the head assembly. If your door is
oversized, locate two 9-in. x 1

³₄

-in. steel

spacers shipped in the small parts carton.
(The spacers are further identified by a
hole at each end.)

2.

Remove the head/fabric roll assembly from the 
shipping crate.

Before the head/fabric roll assembly is
lifted into place, make sure both side col-
umns are secured to the building wall.

Also, the head/fabric roll assembly must
be secured to the forklift before lifting it in
place. Failure to properly secure the side
columns or the head/fabric assembly can
result in serious personal injury and prop-
erty damage. DO NOT remove the forklift
from under the head/fabric roll assembly
until it is secured to both side columns.

Use care when handling the fabric roll to
ensure that the fabric is not torn or dam-
aged. DO NOT remove the shipping bands
holding the fabric to the roll.

IMPORTANT: Install the head/fabric roll

assembly with the bottom bar/
fabric roll coming off the back of
the drum assembly.

3.

Using a forklift, lift the head/fabric roll assembly in 
place.

4.

Position the head assembly in front of the pair of 
holes near the top of each side column. Align the 
holes in the motor mounting bracket with the holes 
in the side column. (See Figure 18.)

IMPORTANT: If your door is oversized, two

large spacers were included in
the small parts carton. Failure to
install a spacer between the
motor mounting bracket and
flange bearing assembly could
result in damage to the door.
(See 

Figure 18

 and 

Figure 19

.)

5.

Attach the motor mounting bracket to the side col-
umn using two 

¹₂

-13 x 1

¹₄

-in. serrated-flange hex 

screws and nuts (or two 

¹₂

-13 x 2-in. screws and 

nuts if spacers are required, or nuts only if 6-in. 
screws were installed earlier). DO NOT tighten the 
hex nuts at this time. (See Figure 18.)

Figure 18

6.

Slide the flange bearing assembly over the drum 
shaft at the non-drive end of the head/fabric roll 
assembly. (See Figure 19.)

IMPORTANT: If your door requires spacers, be

sure to install a spacer between
the flange bearing assembly and
the side column. (See 

Figure 19

.)

A7500247

Serrated-Flange
Hex Screws and Nuts

IMPORTANT:

 Install Spacer between

Motor Mounting Bracket and Side
Column (If Spacer Is Supplied)

Motor Mounting
Bracket

Side Column

Содержание Pharma-Roll

Страница 1: ...Pharma Roll Installation Manual Revision January 15 2009 0715009 Rytec Corporation 2007...

Страница 2: ......

Страница 3: ...3 Concrete Block or Brick Walls 3 Wood Block Brick or Insulated Walls 3 Insulated Wall 3 Insulated Wall 3 LOCATING CENTERLINE OF DOOR OPENING 4 LOCATING SIDE COLUMNS 4 SIDE COLUMNS 5 SIDE COLUMN MOTO...

Страница 4: ...leed Check 14 Reversing Edge Switch Sensitivity Adjustment 14 PNEUMATIC KILL SWITCH CHECK AND ADJUSTMENT 15 Kill Switch Check 15 Kill Switch Air Bleed Adjustment 15 Kill Switch Sensitivity Adjustment...

Страница 5: ...ly covering the control panel and electrical components of that door That schematic was shipped inside the control panel DOOR SERIAL NUMBER S Your DOOR SERIAL NUMBER information can be found in three...

Страница 6: ...S 1 A forklift must be supplied by the customer dealer or installer 2 Two installers are required NOTE One installer must be a qualified electrical technician and all electrical work must meet applica...

Страница 7: ...mer Support Depart ment at 800 628 1909 NOTE Use in diameter threaded through bolts or in diameter threaded rods to anchor the door to all wall applications Use in diameter concrete anchor bolts to an...

Страница 8: ...han the production width of the door If the width of the opening is narrower than the width of the door do not proceed with the installation Contact your Rytec repre sentative or Rytec Customer Suppor...

Страница 9: ...edge of the layout line See Figure 12 Figure 12 It is critical that the side columns are mounted level and square to the wall and floor both vertically and horizontally A 4 ft level and carpenter s sq...

Страница 10: ...de a side column motor support will be sup plied with the small parts box as seen in Figure 13 Failure to install this part prop erly may result in equipment failure and or personal injury Figure 13 I...

Страница 11: ...The U brackets and mounting hardware were shipped in the small parts carton See Figure 16 IMPORTANT Attach the large U bracket to the drive motor side column with the screw hole located 6 in from the...

Страница 12: ...bly until it is secured to both side columns Use care when handling the fabric roll to ensure that the fabric is not torn or dam aged DO NOT remove the shipping bands holding the fabric to the roll IM...

Страница 13: ...the hardware securing the motor and the flange bearing mounting brackets to the side col umns Then tighten the set screw to lock the flange bearing to the drum shaft See Figure 20 and Figure 21 Figur...

Страница 14: ...e release lever located on the motor brake assembly The brake must be in the engaged position See Figure 23 Figure 23 NOTE When released the motor brake will de fault to the engaged position 2 Cut and...

Страница 15: ...e following procedure NOTE The door is shipped with two sets of photo eyes One set monitors the back side of the door The other set monitors the front side of the door Each set consists of an emitter...

Страница 16: ...f each wire cable onto the end of the photo eyes NOTE Be sure the path through which the wire cables are routed hides and protects them from damage If necessary run conduit to each mounting bracket to...

Страница 17: ...oop is used all wiring from the fused disconnect to the control box and from the control box to the motor mount side column as well as conduit running from the control box to the floor is pro vided by...

Страница 18: ...djustment To check the air bleed turn the air bleed adjustment screws located on the front and back of the switch fully clockwise but do not overtighten Then turn the screws back counter clockwise one...

Страница 19: ...nt on this page If the kill switch operated properly Reinstall the bottom bar into the side column See RESET TING BOTTOM BAR ASSEMBLY on page 16 Figure 35 Figure 36 Kill Switch Air Bleed Adjustment 1...

Страница 20: ...properly aligned Placing your hand in front of the receiver breaks the light path and causes the yellow light to go out Removing your hand causes the yellow light to go back on Photo Eye Test Personne...

Страница 21: ...42 2 Attach the hood cover section to the head extrusion See Figure 43 Secure cover to extrusion and end panels using 14 x in LG 410 SS screws Figure 43 3 Attach motor cover to end cover and hood with...

Страница 22: ...n if reversing edge on the bottom bar comes in contact with an object during the down travel of the door panel See PNEUMATIC REVERSING EDGE SWITCH ADJUSTMENT on page 14 for test and adjustment procedu...

Страница 23: ...NOTES 19...

Страница 24: ......

Отзывы: