background image

998000445

3-26-21 (REV:03)

WARNING!

To reduce the risk of injury, user must read and understand the operator’s 

manual for their chemical sprayer and this instruction sheet. Always wear 

eye protection with side shields marked to comply with ANSI Z87.1, as well 

as any other safety equipment required due to the solution being sprayed. 

Ensure compatibility and fit before using this accessory. Do not use this 

accessory if a part is damaged or missing. If you are not comfortable per-

forming any of the functions described in these instructions, take your unit 

to an authorized service center.

WARNING:

Do not use this product if it is not completely assembled or if any parts 

appear to be missing or damaged. Use of a product that is not properly 

and completely assembled or has dam aged or missing parts could result 

in serious personal injury.

IMPORTANT SAFETY INSTRUCTIONS

 

Follow all guidelines and warnings in the PSP02 product manual.

 

 

Remove backpack before filling the tank with chemicals.

 

Ensure sprayer connections are properly secured and working properly 

before using or transporting.

 

The backpack straps are subject to wear and deterioration and should be 

checked each time it is used.

 

Do not overreach. Keep proper footing and balance at all times. Do not use 

on a ladder or unstable support. Stable footing on a solid surface enables 

better control of the product in unexpected situations.  

 

Know the contents of the chemical being sprayed. Read all Safety Data 

Sheets (SDS) and container labels provided with the chemical. Follow the 

chemical manufacturer’s safety instructions. It is a violation of federal law to 

use an EPA-approved disinfectant in a manner inconsistent with its labeling.

CONNECTING THE ADAPTOR

See Figures 1 - 3.

 

Unlock and remove the chemical sprayer adaptor from the adaptor storage 

area on the 2 gallon tank. 

 

Before use, attach the adaptor to the PSP02 sprayer, then attach the hose 

quick connect. 

 

Attach the threaded end of the supplied chemical hose to the 2 gallon tank. 

Tighten securely.

 

Remove the battery pack from the PSP02 electrostatic sprayer.

 

Unlock and remove the 1 liter tank from the bottom of the PSP02 electrostatic 

sprayer.

 

Place the adaptor on the bottom of the PSP02 electrostatic sprayer. Lock 

the latches to secure the tank in place.

 

Attach the female coupler on the other end of the hose to the adaptor.

 

NOTE:

 Always make sure that the hose is attached and securely tightened 

to both the tank and the adaptor to prevent leakage. 

  

NOTE: 

To prevent leakage, always disconnect the hose quick connect from 

the adaptor and sprayer when not in use or when transporting.

FILLING THE 2 GALLON TANK

See Figure 4.

 

 

Know the contents of the chemical being sprayed. Read all Safety Data 

Sheets (SDS) and container labels provided with the chemical.

 Follow the 

chemical manufacturer’s safety instructions. It is a violation of federal law to 

use an EPA-approved chemical in a manner inconsistent with its labeling.

 

Place the 2 gallon tank upright on a flat level surface.

TECHTRONIC INDUSTRIES POWER EQUIPMENT

P.O. Box 1288  

   Anderson, SC 29622 USA

1-800-525-2579   

   www.ryobitools.com

CHEMICAL SPRAYER TANK ADAPTOR

PSP02AD

Use with RYOBI PSP02 Handheld Electrostatic Sprayer ONLY

Fig. 4

Fig. 2

 

Remove the cap from the top of the 2 gallon tank.

 

Carefully pour up to 2 gallons of liquid into the tank. Do not overfill.

 

Replace the cap.

 

NOTE: 

Wipe the outside of the tank with a dry cloth and clean up any spills 

before putting the backpack tank on your back. 

 

NOTE:

  If mixing a concentrated solution, follow the instructions on the 

chemical container for proper ratio usage per the manufacturer’s direction.

USING THE CHEMICAL SPRAYER TANK ADAPTOR

See Figure 5.

 

Slip your arms through the backpack straps and position the tank against 

your back.

 

Adjust the straps until the tank rests comfortably against the small of your 

back.

 

Reinstall the battery pack into the PSP02 electrostatic sprayer.

 

Move the lever on the shut-off valve in the hose to the OPEN position.

 

You are now ready to spray according to the instructions in your chemical 

sprayer operator’s manual.

 

NOTE: 

Make sure the lever on the shut-off valve is in the CLOSED position 

when the sprayer is not in use to avoid any unwanted dripping from the 

nozzle.

CLEANING THE UNIT

See Figure 6.

WARNING:

Always store and dispose of chemicals properly. Disposal of contaminated 

rinse water should be performed according to local ordinances and bylaws.

DRAINING THE TANK

If there is any liquid left in the tank after spraying, the tank should be drained 

before cleaning.

 

Remove the battery pack.

  Disconnect the hose from adaptor and unscrew the cap from the tank. 

  Drain the contents of the tank and the hose through the fill opening.

 

NOTE:

 Drain the contents back into the original container. Do not store 

chemicals in the tank.

  Follow all manufacturer and SDS guidelines for the chemical being used.

CLEANING THE TANK AND SPRAY LINES

 

Do not leave residue or spray material in the tank after using the sprayer. 

Clean after each use.

 

Fill the tank about one-third full with clean water. A small amount of mild 

household detergent may be added.

 NOTE: 

Never use flammable chemicals or abrasive cleaning agents to clean 

the tank.

 

Wipe the outside of the tank with a clean, dry cloth.

  Replace the cap.

  Reinstall the battery pack. Spray until the tank has been emptied. Make sure 

to direct the spray toward an area that will not be damaged by the spray 

solution.

  Refill and repeat the procedure with clean water. It may be necessary to 

rinse the tank more than once, then drain again as directed above.

  Allow all pieces to completely dry before reinstalling parts and storing the 

unit. 

 

NOTE:

 Store the sprayer in an upright position. 

DO NOT

 store the sprayer 

on its side.