5
English
If the tool stops during use, release the trigger to reset and
resume operation. If the tool still does not work, the battery
needs to be recharged.
Note: The LED charge indicator light will not work if the
battery protection feature has caused the battery pack to
stop powering the tool. When the battery pack resets itself,
the LED will again function.
LED FUNCTIONS OF CHARGER
See figure 2
Charger LED
indicator
Battery
pack status Red LED
Green
LED
Action
Power
Without
battery
pack
ON
OFF
Ready to
charge battery
pack.
Evaluate Hot battery
pack
Flashing
OFF
When battery
pack reaches
cooled
temperature,
charger begins
fast charge
mode.
Evaluate
Cold
battery
pack
Flashing
OFF
When battery
pack reaches
warmed
temperature,
charger begins
fast charge
mode.
Evaluate
Deeply
discharged Flashing
OFF
Charger
pre-charges
battery until
nomal voltage
is reached,
then begins fast
charge mode.
Defective Defective Flashing Flashing
Battery pack
or charger is
defective.
• If defective, try to repeat the conditions a second time
by removing and reinstalling the battery pack. If the LED
status repeats a second time, try charging a different
battery.
• If a different battery charges normally, dispose of the
defective pack.
• If a different battery also indicates "Defective," the
charger may be defective.
Charging
Fast
charging
ON
Flashing
—
Full
—
OFF
ON
Fast charging
is complete;
charger
maintains
charge mode.
Note: There is a low input voltage audible alarm for less
than 10.5 V DC input. The charger will shut off when input
voltage is less than 10.5 V or more than 15 V.
CHARGING THE BATTERY PACK
This charger will accept Ryobi 14.4V and 18V lithium-ion
battery packs and Ryobi 14.4V and 18V nickel-cadmium
battery packs.
Use only these Ryobi 14.4V and 18V battery packs with
this charger.
Compatible
Battery
Pack
Voltage
Charger
Input
Chemistry Battery
Capacity
No. of
Cell per
Battery
130224052
14.4 V
220V-240V,
50Hz-60Hz
AC only
Ni-cd
1.3 Ah
12
130427003
1.5 Ah
12
BPL1414
Li-ion
1.4 Ah
4
ABP-1815
18 V
Ni-cd
1.5 Ah
15
ABP-1813
1.3 Ah
15
ABP1801G
1.7 Ah
15
ABP1802G
1.7 Ah
15
RB18N15
1.5 Ah
15
BPL-1815
Li-ion
1.4 Ah
5
BPL-1820
2.4 Ah
10
BPL-
18202PK
2.4 Ah
10
RB18L13
1.3 Ah
5
RB18L15
1.5 Ah
5
RB18L25
2.5 Ah
5
RB18L26
2.6 Ah
10
RB18L40
4.0 Ah
10
RB18LL40
4.0 Ah
10
Battery packs for this tool are shipped in a low charge
condition to prevent possible problems. Therefore, you
should charge them until the green LED on the front of the
charger comes on.
CHARGING A BATTERY PACK
If the charger does not charge the battery pack under
normal circumstances, return both the battery pack and
charger to your nearest authorized service center for
electrical check.
Use battery pack only with the recommended charger.
Connect the charger to the power supply. Make sure
the power supply is 12 V DC.