Cleaning the Spark Arrestor
Cleaning the spark arrestor is required for maximum generator performance. The muffler is mounted inside
the generator housing. The cleanout plugs are located on the bottom side of the muffler, accessible through
the air outlet open in the bottom of the generator.
A hot muffler can cause severe burns, let the muffler cool down before removing or installing the
cleanout plugs.
Please refer to Figure 17 below when cleaning out the spark arrestor muffler.
1.
Remove the cleanout plugs from the bottom of the muffler.
2.
Restart the generator and load it to near full power. Let the generator run for about five minutes to
expel the soot deposits inside the muffler.
3.
Stop the generator, allow the muffler to cool, then reinstall the cleanout plugs.