11.2
Daily checks
Before the wet separator is used
the following functions must be
checked and any necessary work performed:
Functional test of degasification valve.
Fill the liquid container with a suitable sealing liquid.
Check the fill level of the liquid container (do this also at
regular intervals during operation).
After the wet separator has been used
the following functions
must be checked and any necessary work performed:
Drain and clean the liquid container.
Clean the viewing windows in the liquid container.
Clean the window of the capacitive fill level monitoring in the
liquid container.
If suction power is reduced, the liquid container, the swirl filter,
the moisture separator and the filter cartridges must be cleaned.
If the filter cartridges are very dirty they must be exchanged.