USE AND MAINTENANCE MANUAL R68090150
ORIGINALE
RUTHMANN ITALIA S.r.l. Via Santa Maria del Piano di sotto,91/B
–
47854 Montescudo-Monte Colombo (RN) - ITALIA
pag. 62
9.11. MICROSWITCHES AND SAFETY SENSORS
Check the following parts:
•
Check integrity
•
Make sure nor water neither humidity is within contacts
•
Check the fixing
•
Check the working
!
WARNING
DANGER
In case of failure, repair or replace.
9.12. REPLACEMENT OF THE FILTER CARTRIDGE
Replace the cartridge as follow:
a. Check key
1
and unscrew filter wrap
2
.
b. Extract cartridge
3
.
c. Wash the filter wrap by means of solvent liquid.
d. Insert a new cartridge.
e. Screw filter wrap
2
.
!
WARNING
WARNING
Do not disperse pollutant liquids, used parts and maintenance remnants. Dispose of them
respecting the rules in force.
9.13. MEWP DEMOLITION
The MEWP demolition must be done by an authorized staff, who can disassemble and separate the
components according to their nature. The materials must be delivered to recyclable-waste collection
centres, in order to enable the separation and treatment of the polluting substances, according to the rules
in force in your country.