Hardware Installation and Reference Guide Product Overview
The RG-S6220-H series switches support 1+1 power supply redundancy. To improve the stability and reliability of
the entire system, it is recommended to configure 1+1 power supply redundancy. When the two power supply
modules work normally, the switch is in the status of current sharing.
It requires at least one power supply module to work normally. Filler panels need to be installed in the unoccupied
power supply module slots to ensure ventilation and heat dissipation and avoid dusts.
Heat Dissipation
The working temperature of the RG-S6220-48XT6QXS-H switches is 0
º
C to 45
º
C, or 32
º
F to 113
º
F, and the heat
dissipation design needs to ensure the stability, safety and maintainability in such environment. The RG-S6220-H
series switches adopt fan ventilation and forced convection to ensure the device can work normally in specified
environment. Dust the device every three months to avoid blocking the ventilation openings.
The RG-S6220-48XT6QXS-H supports fan module M6220-FAN-F and provides fan speed regulation, fan failure
warning, and fan hot swapping.
Figure 1-11 Ventilation and Heat Dissipation of the RG-S6220-48XT6QXS-H
Leave sufficient space in the front and at the back of the chassis (at least 20cm) for ventilation.
It requires at least two fan modules to work normally. Filler panels need to be installed in the unoccupied fan
module slots to ensure ventilation and heat dissipation and avoid dusts.
1.3 RG-S6220-32QXS-H
Specifications
Model
RG-S6220-32QXS-H
CPU
Quad-core processer, 1.0GHz
BOOT ROM
8MB
FLASH Memory
1GB
SDRAM
DDRIII 2GB
Extension Module
Slot
Unsupported
Extension Module
Unsupported
Fan Slot
3 (support 2+1 redundancy, configure at least two fan modules in one switch)
Fan Module
M6220-FAN-F