5. Extension port 2 status indicator
6. RPS link indicator
7. POE mode switchover button
8. Console port
9. 10/100Base-T adaptive Ethernet port
10. 10/100Base-T adaptive Ethernet port indicator
11. 10/100/1000Base-T adaptive Ethernet port
12. 100/1000Base-X SFP port
13. 10/100/1000Base-T adaptive Ethernet port indicator
14. 100/1000Base-X SFP port indicator
Ports on the Backpanel
Figure 1-21 Schematic diagram of the RG-S3760E-48P backpanel - 1
1. Grounding pole
2. RPS input interface
3. 3-core AC power interface
4. Power defense shedding plug
5. Fan outlet
6. Extension module slot
Power Supply System
The RG-S3760E-48P adopts the AC power input and redundant power input.
AC input:
Rated voltage range: 100-240V~
Maximum voltage range: 90-264V~
Frequency:
50-60Hz
Rated current:6 A
Power cable current: 10A
Redundant power input:
The switch power can be supplied by the redundant power input or both the AC input and redundant power input.
When both the AC input and the redundant power input are available, the switch power is supplied by the AC power
input; while the AC input is unavailable, the switch power supply switches to the redundant power input seemlessly.