RG-S2910-H Series Switch 

Hardware Installation and Reference Guide V1.22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание RG-S2910-10GT2SFP-UP-H

Страница 1: ...RG S2910 H Series Switch Hardware Installation and Reference Guide V1 22...

Страница 2: ...or by any means without the prior written consent of Ruijie Networks is prohibited Exemption Statement This document is provided as is The contents of this document are subject to change without any n...

Страница 3: ...ie Networks Website http www ruijienetworks com Service Email service_rj ruijienetworks com Technical Support http www ruijienetworks com service aspx Technical Support Hotline 86 4008 111 000 Related...

Страница 4: ...s 1 4 are HPoE capable 4 1 RG S2910 10GT2SFP UP H 10 Ports 1 8 are HPoE capable 2 1 RG S2910 24GT4XS UP H 24 All are PoE capable Ports 1 4 are HPoE capable 4 1 The SPF ports are downward compatible wi...

Страница 5: ...Ports 5 24 support the maximum power output of 30W The maximum output power of PoE PoE HPoE is 370W The HPoE ports support the maximum power supply of 60W only when connected with HPoE PDs For example...

Страница 6: ...a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Product Appearance On the front panel the RG S2910 24GT4SFP UP H Ether...

Страница 7: ...G S2910 24GT4SFP UP H Note 1 Grounding pole Power Supply The RG S2910 24GT4SFP UP H switch adopts AC or HVDC power input AC input Rated voltage range 100V to 240V Maximum voltage range 90V to 264V Fre...

Страница 8: ...Meaning System status LED Status Off The switch is not receiving power Blinking green The system is being initialized Continuous blinking indicates errors Solid green The switch is operational Solid y...

Страница 9: ...en The port is connected at 1000 Mbps Blinking green The port is receiving or transmitting traffic at 1000 Mbps 1 2 RG S2910 24GT4XS UP H Technical Specifications Model RG S2910 24GT4XS UP H CPU Built...

Страница 10: ...PoE load Less than 460W with PoE full load Operating Temperature 0 to 50 Storage Temperature 40 to 70 Operating Humidity 10 to 90 Storage Humidity 5 to 95 Fan Speed adjustment and fault alarm Temperat...

Страница 11: ...ver Button 6 Console port 7 10 100 1000Base T auto sensing Ethernet port 8 SFP port Long press PoE Mode Switch Over Button for above 2 seconds to switch the display mode between PoE mode and port rate...

Страница 12: ...on thereby ensuring normal function of the device in the specified environment 10 cm distance space should be reserved at both sides and the back plane of the cabinet to allow air circulation It is re...

Страница 13: ...he port is not connected Solid green The port is connected at 1000 Mbps Blinking green The port is receiving or transmitting traffic at 1000 Mbps Solid yellow The port is connected at 10 100 Mbps Blin...

Страница 14: ...HVDC input Voltage range 192V to 290V Current range 0A to 6A EEE Supported PoE Ports 1 8 are HPoE capable with the maximum power output of 95W The maximum output power is as follows AC input 90 to175V...

Страница 15: ...switch is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Product Appearance On the front panel...

Страница 16: ...port 11 Reset Button Long press PoE Mode Switch Over Button for above 2 seconds to switch the display mode between PoE mode and port rate mode Back Panel Figure 1 11 Back Panel of RG S2910 10GT2SFP U...

Страница 17: ...and both planes of the cabinet to allow air circulation It is recommended to clean the device once every 3 months to avoid dust from blocking vents Figure 1 12 shows the flow scheme of heat dissipati...

Страница 18: ...ng green The port is receiving or transmitting traffic at 1000 Mbps Solid yellow The port is connected at 10 100 Mbps Blinking yellow The port is receiving or transmitting traffic at 10 100 Mbps RJ45...

Страница 19: ...l power supplies and dismantle all power modules 2 1 3 Electricity Observe local regulations and specifications when performing electric operations Relevant operators must be qualified Before installi...

Страница 20: ...the installation site must meet the following requirements 2 2 1 Ventilation For the RG S2910 H a sufficient space at least 10 cm distances from both sides and the back plane of the cabinet should be...

Страница 21: ...the requirements for the dust content and granularity in the equipment room Table 2 2 Requirements for the Dust Content and Granularity in the Equipment Room Dust Unit Density Diameter 0 5 m Particles...

Страница 22: ...e grounding wire should be at least 0 75 mm2 18 AWG Use the 3 core power supply line The sectional area of each pin should be at least 0 75 mm2 or 18 AWG Lightning Grounding The lightning protection s...

Страница 23: ...rference often affects the power supply of the equipment but can be controlled by a filter Radiated interference may affect any signal path in the equipment and is difficult to shield For the AC power...

Страница 24: ...lation please confirm the following points Whether ventilation requirements are met for the switch Whether the requirements of temperature and humidity are met for the switch Whether power cables are...

Страница 25: ...uency large current devices If necessary electromagnetic shielding should be adopted For example use interface cables to shield cables 100 meter network cables should be laid inside the equipment room...

Страница 26: ...re 3 3 Figure 3 3 3 3 2 Mounting the Switch on the Wall The RG S2910 H series switch can be mounted on the wall as shown in the following figure Attach the mounting brackets to the switch with the sup...

Страница 27: ...3 4 Attaching the Switch on the Wall SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON COMBUSTIBLE SURFACE ONLY 3 3 3 Mounting the Switch on a Table Attach the four rubber feet to the recessed areas on...

Страница 28: ...ply so as to avoid any personal injury or damage to the component due to connection errors Check that the ground line is connected Check that the cables and power input cables are correctly connected...

Страница 29: ...port of the PC Step 2 Connect the end of the console cable with RJ45 to the console port of the switch Setting HeperTerminal Parameters Step 1 Start the PC and run the terminal simulation program on t...

Страница 30: ...layed Choose the serial port used currently in the column use when connecting Figure 4 3 4 After choosing the serial port click OK to display the serial port parameter setting interface set the baud r...

Страница 31: ...onsole port of the switch The HyperTerminal is started and the parameter settings are correct 4 2 2 Checking after Program Startup Recommended After power on you are recommended to perform the followi...

Страница 32: ...Check whether the service interface forwards data normally...

Страница 33: ...in loose contact Check whether the power socket at the equipment room is normal and whether the power cable of the switch is in good contact The status indicator is red Fan alarm Temperature alarm Che...

Страница 34: ...mon working mode with the connected switch Replace the twisted pair cable Check that the port configuration has the common working mode with the connected switch The fiber port cannot be connected The...

Страница 35: ...all of which must be connected Figure A 1 shows the connections of the twisted pairs used by the 1000BASE T port Figure A 1 Four Twisted Pairs of the 1000BASE T In addition to the above cables the 10...

Страница 36: ...or the optical fiber ports select single mode or multiple mode optical fibers for connection according to the fiber module connected The connection schematic diagram is shown in Figure A 4 Figure A 4...

Страница 37: ...3 17 0 GE SFP LX 1310 SMF No 9 5 3 20 3 GE SFP SX SM1550 BIDI 1550TX 1310RX MMF No 10 5 17 3 GE SFP SX SM1310 BIDI 1310TX 1550RX MMF No 10 5 17 3 GE eSFP SX MM850 850 MMF Yes 9 5 3 17 0 GE eSFP LX SM1...

Страница 38: ...62 5 125 275m 50 125 550m GE SFP LX LC SMF 9 125 10km Mini GBIC GT RJ45 Category 5 or above UTP or STP 100m For the optical module with transmission distance exceeding 40 km and more one on line opti...

Страница 39: ...2000 OM3 500 OM2 400 OM1 300m 82m 66m XG SFP SR SM1270 BIDI LC MMF 50 125 2000 OM3 300m XG SFP SR SM1330 BIDI LC MMF 50 125 2000 OM3 300m XG SFP LR SM1270 BIDI LC SMF 9 125 N A 10km XG SFP LR SM1330 B...

Страница 40: ...G SFP AOC5M Active SFP 5 10 3125 No No extra cables are needed when SFP cables are used Inserting the two ends of a SFP cable into corresponding ports facilitates inter communication between the two p...

Страница 41: ...at the PE terminal of the power arrester has been well grounded After connecting the switch AC power plug to the socket of the power arrester lightning protection cable row lightning protection functi...

Страница 42: ...s in good contact with the switch grounding terminal and the framework 4 According to the description on the Ethernet Port Arrester Hardware Installation Guide connect the arrester using the adapter c...

Страница 43: ...e grounding line should be as short as possible to ensure that it is in good contact with the switch grounding terminal Use the multimeter to confirm the contact condition after the grounding Incomple...

Страница 44: ...er than seven times their respective diameters The bend radius of a common coaxial cable should be greater than seven times its diameter The bend radius of this type of cables that often bend or suffe...

Страница 45: ...traversed by cables should have a smooth and fully rounding surface or an insulated lining Proper buckles should be selected to bundle up cables It is forbidden to connect two or more buckles to bund...

Страница 46: ...guide rails of moving parts The power cables connecting moving parts such as door grounding wires should be reserved with some access after assembled When the moving part reaches the installation pos...

Страница 47: ...bunches with cables in cable bunches clean and straight Binding by using buckles should be performed according to Table D 1 Cable Bunch Diameter mm Binding Space mm 10 80 150 10 30 150 200 30 200 300...

Страница 48: ...as away from dust If the dust is unavoidable keep the door and window away from the pollution source The machine room should be away from the residential area Otherwise the machine room should meet t...