CLI Reference
GRTD Configuration Commands
commands
diagnostic
monitor
interval
Set monitoring interval.
diagnostic
monitor
threshold
Set
the
maximum
number
of
consecutive failed monitoring tests.
Platform
description
N/A
show diagnostic description
Use this command to display detailed descriptions of test items in privileged EXEC mode,
mainly describing the meanings of test items.
show diagnostic description
[
slot
slot_id
[
sub_system
subsys_id
]]
test
{
all
|
test-id
|
range
test-range
}
Parameter
description
Parameter
Description
slot
slot_id
Slot ID
sub_system
subsys_id
(Optional) Subsystem ID (value range: 0-1), whose
meaning is equivalent to cpu id in the show version
command.
test
{
all
|
test-id
|
range
test-range
}
Test items.
all
means all items;
range
means a
range, for example, from item m to item n.
Default
This command has no default setting.
Command
mode
Privileged EXEC mode
Usage
guidelines
Use the
show diagnostic description
command to display
detailed descriptions of test items.
Examples
Example 1: The following example shows the detailed description of
item 1 of module 2.
ruijie#show diagnostic description slot 2 test 1
TestLoopback:
This test verifies the data path between the mainboard and network
ports of a line card.
ruijie#
Example 2: The following example shows the detailed descriptions of
Содержание RG-S2600G-I Series
Страница 1: ...1 CLI Reference Guide RG S2600G I Series Switches RGOS 10 4 3b16...
Страница 5: ...5...
Страница 192: ...CLI ReferenceInterface Configuration Commands Interface Configuration Commands Platform Description...
Страница 452: ...CLI Reference DHCP Configuration Commands commands clear ip dhcp server statistics Delete the DHCP server statistics...
Страница 505: ...CLI Reference TCP Configuration Commands Related commands Command Description...
Страница 513: ...CLI Reference IPv4 REF Configuration Commands Platform description N A Command history Version Description...
Страница 514: ...IP Routing Configuration Commands 1 IP Routing Configuration Commands...
Страница 527: ...Multicast Configuration Commands 1 IGMP Snooping Configuration Commands 2 MLD Snooping Configuration Commands...
Страница 642: ...CLI Reference TACACS Configuration Commands host...
Страница 652: ...CLI Reference 802 1X Configuration Commands Ruijie config if end...
Страница 744: ...CLI Reference CPU Protection Configuration Commands Caution This command is not supported on S3760 series...
Страница 773: ...CLI Reference IPSource Guard Configuration Commands Platform description This command is supported on all switches...
Страница 776: ...CLI Reference ND Snooping Configuration Commands...
Страница 901: ...CLI Reference NFPP Configuration Commands...
Страница 902: ...ACL QOS Configuration Commands 1 ACL Configuration Commands 2 QoS Configuration Commands...
Страница 999: ...CLI Reference RLDP Configuration Command Command mode Privileged EXEC mode...
Страница 1004: ...CLI Reference DLDP Configuration Commands Ruijie config if FastEthernet 0 0 clear dldp 20 1 1 1 10 1 1 1...
Страница 1005: ...CLI Reference DLDP Configuration Commands...
Страница 1146: ...CLI Reference VSU Configuration Commands Examples Ruijie vsu conver to stack Related Commands Command Description N A N A...
Страница 1191: ...CLI Reference Guide RSPAN Configuration Commands Platform Description N A...
Страница 1192: ...CLI Reference Guide...