Ruijie RG-ES100 Series Switches Hardware Installation and Reference Guide                                 

Appendix B Mini-GBIC and SPF+ Module 

Mini-GBIC-LX-SM1310 

LC 

SMF 

9/125 

10km 

GE-eSFP-SX-MM850 

LC 

MMF 

62.5/125 

275m 

50/125 

550m 

GE-eSFP-LX-SM1310 

LC 

SMF 

9/125 

10km 

GE-SFP-LX-SM1310 

LC 

SMF 

9/125 

10km 

Mini-GBIC-LH40-SM1310 

LC 

SMF 

9/125 

40km 

GE-SFP-SX-SM1310-BIDI 

LC 

MMF 

50/125 

500m 

GE-SFP-SX-SM1550-BIDI 

LC 

MMF 

50/125 

500m 

GE-SFP-LX20-SM1310-BIDI 

LC 

SMF 

9/125 

20km 

GE-SFP-LX20-SM1550-BIDI 

LC 

SMF 

9/125 

20km 

GE-SFP-LH40-SM1310-BIDI 

LC 

SMF 

9/125 

40km 

GE-SFP-LH40-SM1550-BIDI 

LC 

SMF 

9/125 

40km 

MINI-GBIC-ZX50-SM1550 

LC 

SMF 

9/125 

50km 

MINI-GBIC-ZX80-SM1550 

LC 

SMF 

9/125 

80km 

MINI-GBIC-ZX100-SM1550 

LC 

SMF 

9/125 

100km 

GE-SFP-SX 

LC 

MMF 

62.5/125 

275m 

50/125 

550m 

GE-SFP-LX 

LC 

SMF 

9/125 

10km 

Mini-GBIC-GT 

RJ45   

Category 5 (or above ) UTP or STP 

100m 

 

 

For the optical module with transmission distance exceeding 40 km and more, one on-line optical attenuator should 

be added on the link to avoid the overload of the optical receiver when short single-mode optical fibers are used. 

 

Optical modules generate laser. Do not stare at light source. 

 

To keep optical modules clean, please use dust caps when the modules are not connected with fibers. 

 

No extra cables are needed when SFP cables are used.  Inserting the two ends of a SFP cable into corresponding 

ports facilitates inter-communication between the two ports. 

Table B-8 Specifications of SFP BIDI Optical Module Pairs 

Rate/Distance 

Module Pairs 

1000M/500m 

GE-SFP-SX-SM1310-BIDI 

GE-SFP-SX-SM1550-BIDI

 

1000M/20km 

GE-SFP-LX20-SM1310-BIDI 

GE-SFP-LX20-SM1550-BIDI 

1000M/40km 

GE-SFP-LH40-SM1310-BIDI 

GE-SFP-LH40-SM1550-BIDI 

 

The BIDI modules must be used in pairs (e.g., GE-SFP-LX20-SM1310-BIDI and GE-SFP-LX20-SM1550-BIDI). 

Содержание RG-ES100 Series

Страница 1: ...Ruijie RG ES100 Series Switches Hardware Installation and Reference Guide V1 0...

Страница 2: ...or by any means without the prior written consent of Ruijie Networks is prohibited Exemption Statement This document is provided as is The contents of this document are subject to change without any n...

Страница 3: ...Technical Support Website https ruijienetworks com support Case Portal https caseportal ruijienetworks com Community https community ruijienetworks com Technical Support Email service_rj ruijienetwork...

Страница 4: ...se T in the downlink direction 1 1 RG ES109G LP L Technical Specifications Model RG ES109G LP L Power Supply AC input Rated voltage range 100V to 240V Maximum voltage range 90V to 264V Frequency 50 60...

Страница 5: ...rt 9 the flow control is disabled on port 9 but enabled on ports 1 8 When the button is turned to the right position flow control is disabled all ports communication is available and the flow control...

Страница 6: ...Panel of RG ES109G LP L Note 1 Grounding pole 2 Working Mode Switch Over Button 3 Power port 4 Hole for anti theft lock Heat Dissipation The RG ES109G LP L adopts natural heat dissipation thereby ensu...

Страница 7: ...00 Mbps Blinking green The port is receiving or transmitting traffic at 10 100 1000 Mbps 1 2 RG ES126G P L Technical Specifications Model RG ES126G P L Optical Module For details see Appendix B The su...

Страница 8: ...other the flow control is disabled on ports 23 26 but enabled on ports 1 22 When the button is turned to the right position flow control is disabled all ports communication is available and the flow c...

Страница 9: ...ort status LED Back Panel Figure 1 6 Back Panel of RG ES126G P L Note 1 Vent 2 AC power port 3 Grounding pole Heat Dissipation The RG ES126G P L adopts turbine fans for heat dissipation thereby ensuri...

Страница 10: ...onal Solid green The switch is operational RJ45 port PoE status LED 1 24 Off PoE is not enabled Solid green PoE is enabled The port is operational Blinking green Indicates PoE overload 1000Mbps RJ 45...

Страница 11: ...wer Supply AC input Rated voltage range 100V to 240V Maximum voltage range 90V to 264V Frequency 50 60 Hz Rated current 3A Power cord requirement 10A PoE Supports PoE and PoE Ports 1 24 are PoE PoE ca...

Страница 12: ...orts On the back panel it provides an AC power port Figure 1 8 Appearance of RG ES126G LP L Front Panel Figure 1 9 Front Panel of RG ES126G LP L Note 1 Power status LED 2 10 100 1000Base T Link ACT LE...

Страница 13: ...6 LEDs LED Panel Identification State Meaning Power status LED PWR Off The switch is not receiving power Solid on The switch is powered on Ethernet port status LED 1 24 Off The port is not connected...

Страница 14: ...Ruijie RG ES100 Series Switches Hardware Installation and Reference Guide Product Overview Blinking Indicates PoE overload...

Страница 15: ...t be qualified Before installing the device carefully check any potential danger in the surroundings such as ungrounded power supply and damp wet ground or floor Before installing the device find out...

Страница 16: ...ge action current of each leakage protector in the system must be equal to or less than 30mA human body safety current is 30mA When twice of the total leakage current of the system is greater than 30m...

Страница 17: ...nk Static electricity may occur easily and endanger the circuit on the equipment In an environment with high temperature the equipment is subject to even greater harm as its performance may degrade si...

Страница 18: ...to enable the device s upper filter circuit to effective filter the power interface The switch should be far from high power radio transmitting stations radar stations and high frequency and large cu...

Страница 19: ...wer reference ground and yellow green safety cable ground The lightning discharge ground is for the facility only irrelevant to the equipment EMC Grounding The grounding required for EMC design includ...

Страница 20: ...d interference may affect any signal path in the equipment and is difficult to shield For the AC power supply system TN single phase three core power socket with protective earthing conductors PE shou...

Страница 21: ...Confirmations before Installation Before installation please confirm the following points Whether ventilation requirements are met for the switch Whether the requirements of temperature and humidity...

Страница 22: ...s to shield cables 100 meter network cables should be laid inside the equipment room and outdoor cabling of such cables is prohibited If outdoor cabling is necessary take relevant measures for lightni...

Страница 23: ...ng the switch on the wall are as follows Step 1 As shown in Figure 3 4 drill two holes with the diameter of about 5 mm on the wall ensure that the spacing of the two holes is 112 mm and the line of co...

Страница 24: ...ess is as follows Step 1 Attach the mounting brackets to the switch with the supplied screws as shown in Figure 3 5 Figure 3 5 Attaching the Mounting Brackets to RG ES126G P L Left Right Step 2 Use th...

Страница 25: ...ame as that of the RG ES126G P L SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON COMBUSTIBLE SURFACE ONLY 3 3 3 Mounting the Switch on a Table Attach the four rubber pads to the recessed areas on the b...

Страница 26: ...uide Product Installation Place the switch on the table as shown in Figure 3 9 and Figure 3 10 Figure 3 9 Mounting the Switch on the Table Figure 3 10 Mounting the Switch on the Table The device must...

Страница 27: ...mage to the component due to connection errors Check that the ground line is connected Check that the cables and power input cables are correctly connected Check that all interface cables are laid out...

Страница 28: ...d The power cable is correctly connected The power supply voltage complies with the requirement of the switch 4 1 2 Checking after Program Startup Recommended After power on you are recommended to per...

Страница 29: ...wisted pair cable is faulty The length of the cable exceeds 100 m The port has special configuration that has no common working mode with the connected switch Replace the twisted pair cable Check that...

Страница 30: ...e 1000BASE T port uses four pairs of wires for transmission all of which must be connected Figure A 1 shows the connections of the twisted pairs used by the 1000BASE T port Figure A 1 Four Twisted Pai...

Страница 31: ...Connectors and Connection Media Optical Fiber Connection For the optical fiber ports select single mode or multiple mode optical fibers for connection according to the fiber module connected The conn...

Страница 32: ...0 Mini GBIC LX 1310 SMF No 9 5 3 20 3 GE eSFP SX MM850 850 MMF Yes 9 5 3 17 0 GE eSFP LX SM1310 1310 SMF Yes 9 5 3 20 3 GE SFP LX SM1310 1310 SMF No 9 5 3 20 3 Mini GBIC LH40 1310 SMF Yes 2 3 22 3 GE...

Страница 33: ...GBIC GT RJ45 Category 5 or above UTP or STP 100m For the optical module with transmission distance exceeding 40 km and more one on line optical attenuator should be added on the link to avoid the ove...

Страница 34: ...ster has been well grounded After connecting the switch AC power plug to the socket of the power arrester lightning protection cable row lightning protection function implements if the RUN LED is Gree...

Страница 35: ...t Port Arrester Hardware Installation Guide connect the arrester using the adapter cable note that the external network cable is connected to the end of IN while the adapter cable connected to the swi...

Страница 36: ...e as short as possible to ensure that it is in good contact with the switch grounding terminal Use the multimeter to confirm the contact condition after the grounding Incomplete arrester installation...

Страница 37: ...es that often bend or suffer removal insertion should be greater than seven times their respective diameters The bend radius of a common coaxial cable should be greater than seven times its diameter T...

Страница 38: ...cabinet should be smooth without sharp corners The metal hole traversed by cables should have a smooth and fully rounding surface or an insulated lining Proper buckles should be selected to bundle up...

Страница 39: ...e during commissioning The power cords cannot be bundled on the guide rails of moving parts The power cables connecting moving parts such as door grounding wires should be reserved with some access af...

Страница 40: ...in the same cabling direction should be bundled up into cable bunches with cables in cable bunches clean and straight Binding by using buckles should be performed according to Table D 1 Cable Bunch Di...

Страница 41: ...onditions such as windstorm and heavy rain as well as away from dust If the dust is unavoidable keep the door and window away from the pollution source The machine room should be away from the residen...

Отзывы: