RDC6563F Standalone Fiber Cutting Control System User Manual V2.0
34
SHENZHEN RUIDA TECHNOLOGY CO., LTD
PIN15
PUL_A
A motor pulse signal
—
2.14 Input IO
General input IO interface definition, as shown in the following table:
Signal
Definition
Description
I1
General input
IO
Reserved
I2
General input
IO
Reserved
I3
General input
IO
Reserved
I4
General input
IO
Reserved
I5
General input
IO
Reserved
I6
General input
IO
Reserved
I7
Foot switch input
Dedicated input, foot switch input. Connection
method
:
When the pedal is stepped on, input a low
voltage signal to the port. When the pedal is
released, the connection of the port is
disconnected or input a high voltage signal. When
the pedal is depressed for at least 100ms, if the
machine is idle, the work will start. If the machine is
in working state, the work will be suspended. If the
machine is in the pause state, the suspended work
will be restarted, that is, the foot switch and the
[Start/Pause] function on the keyboard are similar.
If the time when the second foot switch is stepped
down from the first time is less than 100
milliseconds, the second foot motion is considered
invalid by the main board.
I8
Machine protection
input
Dedicated input, protection signal input. If the
machine needs to be protected under certain
conditions (such as cover protection), the
protection signal is input from this pin. When the
machine protection is enabled in the factory
parameters, when the input is high or the input is
left floating, the machine is protected, the ongoing
work is paused, and the laser is on off.
I9
Stop input
Dedicated input, external stop button input (low
voltage valid), it likes stop button function on the