Cutting Centre SR 2 BiTurbo
19
Hydraulic hoses must always be replaced at an interval of
2 years (for increased loads and usage*) or 6 years (for
normal loads and usage)! See embossed date.
This represents a measure for the
Preservation of safe
condition
according to para. 10 (1) Operational Safety
(German BetrSichV).
No hazardous situation may arise from extending the
changing intervals which may cause injuries to employees
or other persons!
*
Increased load and usage, e.g. through multiple shift operation or short
cycle times of the machine or pressure pulses.
g)
Check the distance between cut-off knife and grate frame;
adjust if necessary!
h)
Grease all moving parts in the machine compartment! (Chain
and sprockets on the lifting aid drive)
i)
Read operating hours and error log on the tablet PC and ex-
amine any faults that have occurred!
j)
Read the error memory (frequency and servo converter)!
5.3
Repairs and spare parts
As a damaged part on a machine is usually damaged due to causes
unrelated to the part, always carry out a fault diagnosis.
Contact our Service Hotline at +49 7748 523-11 for spare parts or
malfunctions. Please keep the machine type and number to hand.
6
Disposal
All materials and operating fuels must be separated and
disposed of in accordance with nationally applicable regu-
lations!
1.
The following components contain oil:
•
Hydraulic system (unit, cylinder, hoses)
•
Grate drives 1 and 2
•
Cutter drive