TABLE 25 Ethernet port status LED in default mode
LED color
Status of the hardware
Recommended action
Off
A link is not established with the remote port.
•
Verify that the connection to the other network
device has been properly made. Also, make
certain that the other network device is
powered on and operating correctly.
•
Be sure the cable is plugged into both the
device and the corresponding device.
•
Verify that the proper cable type is used and its
length does not exceed specified limits.
•
Check the adapter on the attached device and
cable connections for possible defects.
Replace the defective adapter or cable if
necessary.
•
Verify that the port has not been disabled
through a configuration change. You can use
the CLI. If you have configured an IP address
on the device, you also can use the Web
management interface or Brocade Network
Advisor.
•
If the other actions do not resolve the problem,
try using a different port or a different cable.
Steady green
The port has established a valid link at 1000 Mbps.
None.
Flashing green
The port has established a valid link at 1000 Mbps. Flashing indicates
the port is transmitting and receiving user packets.
None.
Steady amber
The port has established a valid link at 10 or 100 Mbps.
None.
Flashing amber
The port has established a valid link at 10 or 100 Mbps. Flashing
indicates the port is transmitting and receiving user packets.
None.
Interpreting nonport-side LEDs
There are no LEDs found on the nonport-side view of the Ruckus ICX 7150 devices.
Pinging an IP address
To verify that a device can reach another device through the network, enter a command similar to the following at any level of the CLI.
device> ping 10.33.4.7
NOTE
If you address the ping to the IP broadcast address, the device lists the first four responses.
Tracing a route
To determine the path through which a device can reach another device, enter a command similar to the following at any level of the CLI on
the device.
device> traceroute 10.33.4.7
Monitoring the Device
Interpreting nonport-side LEDs
Ruckus ICX 7150 Switch Hardware Installation Guide
98
Part Number: 53-1004928-05
Содержание ICX 7150-24
Страница 6: ...Ruckus ICX 7150 Switch Hardware Installation Guide 6 Part Number 53 1004928 05 ...
Страница 10: ...Ruckus ICX 7150 Switch Hardware Installation Guide 10 Part Number 53 1004928 05 ...
Страница 82: ...Ruckus ICX 7150 Switch Hardware Installation Guide 82 Part Number 53 1004928 05 ...
Страница 90: ...Ruckus ICX 7150 Switch Hardware Installation Guide 90 Part Number 53 1004928 05 ...
Страница 114: ...Ruckus ICX 7150 Switch Hardware Installation Guide 114 Part Number 53 1004928 05 ...
Страница 123: ... 2018 ARRIS Enterprises LLC All rights reserved 350 West Java Dr Sunnyvale CA 94089 USA www ruckuswireless com ...