Device
Maximum output
power rating (DC)
Input voltage
Input line frequency
Maximum input
current
Input line protection Maximum inrush
current
ICX 7150-24P
525 W
100 - 240 VAC
(nominal)
90 - 264 VAC
(range)
50/60 Hz
(nominal)
47 - 63 Hz
(range)
7.23 A (rms)
Line fused
30 A at 115 VAC
60 A at 230 VAC
Cold start @ 25°C
ICX 7150-48
65 W
100 - 240 VAC
(nominal)
90 - 264 VAC
(range)
50/60 Hz
(nominal)
47 - 63 Hz
(range)
5.4 A (rms)
Line fused
40 A at 115 VAC
80 A at 230 VAC
Cold start @ 25°C
ICX 7150-48P
525 W
100 - 240 VAC
(nominal)
90 - 264 VAC
(range)
50/60 Hz
(nominal)
47 - 63 Hz
(range)
11.25 A (rms)
Line fused
30 A at 115 VAC
60 A at 230 VAC
Cold start @ 25°C
ICX 7150-48PF
880 W
100 - 240 VAC
(nominal)
90 - 264 VAC
(range)
50/60 Hz
(nominal)
47 - 63 Hz
(range)
14.45 A (rms)
Line fused
60 A at 115 VAC
120 A at 230 VAC
Cold start @ 25°C
Power consumption (idle configuration)
Idle: No optics or connections to ports installed and system booted up. Fans at nominal speed.
Model name
@100 VAC input
@200 VAC input
@-48 VDC input
Minimum number of
power supplies
Notes
ICX 7150-48ZP
With one power supply
and one fan
0.82 A
89 W
303.68 BTU/hr
0.5 A
85.89 W
293.07 BTU/hr
N/A
1
All ports down, no
optics or cables
connected.
No Load (traffic)
ICX 7150-48ZP
With two power
supplies and two fans
1.14 A
108 W
368.51 BTU/hr
0.7 A
105.4 W
359.64 BTU/hr
N/A
2
All ports down, no
optics or cables
connected.
No Load (traffic)
ICX 7150-C12P
0.22 A
20.10 W
68.60 BTU/hr
0.16 A
19.5 W
68.09 BTU/hr
N/A
1
All ports down, no
optics or cables
connected.
No Load (traffic)
ICX 7150-24
0.25 A
13.88 W
47.37 BTU/hr
0.16 A
13.53 W
46.18 BTU/hr
N/A
1
All ports down, no
optics or cables
connected.
No Load (traffic)
ICX 7150-24P
0.35 A
31.58 W
107.79 BTU/hr
0.29 A
30.64 W
104.58 BTU/hr
N/A
1
All ports down, no
optics or cables
connected.
No Load (traffic)
Ruckus ICX 7150 Switch Technical Specifications
Power consumption (idle configuration)
Ruckus ICX 7150 Switch Hardware Installation Guide
Part Number: 53-1004928-05
105
Содержание ICX 7150-24
Страница 6: ...Ruckus ICX 7150 Switch Hardware Installation Guide 6 Part Number 53 1004928 05 ...
Страница 10: ...Ruckus ICX 7150 Switch Hardware Installation Guide 10 Part Number 53 1004928 05 ...
Страница 82: ...Ruckus ICX 7150 Switch Hardware Installation Guide 82 Part Number 53 1004928 05 ...
Страница 90: ...Ruckus ICX 7150 Switch Hardware Installation Guide 90 Part Number 53 1004928 05 ...
Страница 114: ...Ruckus ICX 7150 Switch Hardware Installation Guide 114 Part Number 53 1004928 05 ...
Страница 123: ... 2018 ARRIS Enterprises LLC All rights reserved 350 West Java Dr Sunnyvale CA 94089 USA www ruckuswireless com ...