![Ruckus Wireless ICX 7150-24 Скачать руководство пользователя страница 104](http://html1.mh-extra.com/html/ruckus-wireless/icx-7150-24/icx-7150-24_hardware-installation-manual_1498875104.webp)
Condition
Operational
Non-operational
Shock
20 G, 11 ms, half-sine wave
33 G, 11 ms, half-sine wave
Vibration
1 G sine, 0.4 gms random, 5-500 Hz
2.4 G sine, 1.1 gms random, 5-500 Hz
Airflow
ICX 7150-48ZP: 40.36 CFM (Maximum), 14.6 CFM (Typical)
ICX 7150-C12P: 0 CFM
ICX 7150-24: 0 CFM
ICX 7150-24P: 37.6 CFM (Maximum), 13.4 CFM (Typical)
ICX 7150-48: 0 CFM
ICX 7150-48P: 38.15 CFM (Maximum), 13.9 CFM (Typical)
ICX 7150-48PF: 50.8 CFM (Maximum), 19.6 CFM (Typical)
N/A
Heat dissipation
Refer to Power Consumption specification sections
N/A
Operating noise
For all fanless ICX 7150 devices and devices in fanless
mode: Less than 12 dBA
ICX 7150-24P, ICX 7150-48P, and ICX 7150-48ZP with
fans running: Maximum of 52 dBA
ICX 7150-48PF with fans running: Maximum of 48 dBA
(fanless mode is not supported)
N/A
Power supply specifications (per PSU)
All the Ruckus ICX 7150 power supply units (PSUs) are fixed and internal to the device. All the PSUs use a C14 inlet and connect to
standard AC power.
Device
Maximum output
power rating (DC)
Input voltage
Input line frequency
Maximum input
current
Input line protection Maximum inrush
current
ICX 7150-48ZP
1740 W
100 - 240 VAC
(nominal)
90 - 264 VAC
(range)
50/60 Hz
(nominal)
47 - 63 Hz
(range)
13 A (rms)
Line fused
30 A at 115 VAC
60 A at 230 VAC
Cold start @ 25°C
ICX 7150-C12P
150 W
100 - 240 VAC
(nominal)
90 - 264 VAC
(range)
50/60 Hz
(nominal)
47 - 63 Hz
(range)
2.78 A (rms)
Line fused
40 A at 115 VAC
60 A at 230 VAC
Cold start @ 25°C
ICX 7150-24
36 W
100 - 240 VAC
(nominal)
90 - 264 VAC
(range)
50/60 Hz
(nominal)
47 - 63 Hz
(range)
3 A (rms)
Line fused
40 A at 115 VAC
80 A at 230 VAC
Cold start @ 25°C
1
For the ICX 7150-C12P, the maximum operating temperature is 40°C when under fully loaded PoE conditions or when installed using the long bracket
(ICX7000-C12-RMK) under a fixed surface. The maximum operating temperature is 35°C when installed using the short bracket (ICX7000-C12-WMK)
under a fixed surface.
Ruckus ICX 7150 Switch Technical Specifications
Power supply specifications (per PSU)
Ruckus ICX 7150 Switch Hardware Installation Guide
104
Part Number: 53-1004928-05
Содержание ICX 7150-24
Страница 6: ...Ruckus ICX 7150 Switch Hardware Installation Guide 6 Part Number 53 1004928 05 ...
Страница 10: ...Ruckus ICX 7150 Switch Hardware Installation Guide 10 Part Number 53 1004928 05 ...
Страница 82: ...Ruckus ICX 7150 Switch Hardware Installation Guide 82 Part Number 53 1004928 05 ...
Страница 90: ...Ruckus ICX 7150 Switch Hardware Installation Guide 90 Part Number 53 1004928 05 ...
Страница 114: ...Ruckus ICX 7150 Switch Hardware Installation Guide 114 Part Number 53 1004928 05 ...
Страница 123: ... 2018 ARRIS Enterprises LLC All rights reserved 350 West Java Dr Sunnyvale CA 94089 USA www ruckuswireless com ...