To
take control of a target keypanel
, do the following:
IMPORTANT:
When you enter the Mirror menu looking for a target panel to Mirror, you can only see panels that are
locally scroll enabled (ie. if they aren’t in your scroll list, you won’t be able to mirror them).
1.
On the keypanel, starting at the Service menu, select
Mirror
.
2.
Press the
SEL button
.
A list of available target keypanels appear in the panel display
.
3.
Using the arrow buttons, scroll to the
target keypanel
.
4.
Press the
SEL button
.
The Supervisor keypanel updates and displays the target keypanel’s image.
To
exit Mirror mode
on the keypanel
, do the following:
1.
On the keypanel, starting at the Service menu, select
Mirror
.
2.
Press the
SEL button
.
The alpha of the target and Exit appear in the panel display
.
3.
Using the arrow buttons or Aux Volume shaft encoder, select
Exit
.
4.
Press the
SEL button
.
The mirroring target and supervisor icons disappear and keypanels go back to normal operation.
Real-Time Control in AZedit (Control Package Only)
Real-Time Control
allows you to make real-time (immediately applied) changes to intercom and keypanel volume controls as
well as muting keypanel microphones, switching headset focus, setting AFK, and enabling tone at selected keypanel ports.
Intercom Volume Controls
Intercom Volume Controls
are used to adjust Crosspoint Listen, Party Line Listen, Port Input Gain, and Port Output Gain.
Adjustments to these different volumes can be done in real-time or modified and sent to the intercom at a later time.
There are two ways to adjust the intercom volume controls;
•
via the Port Volumes window
•
opening the individual gain adjustment screens
By default, intercom volumes are set at +0.0dB.
The range for Crosspoint Listen and Party Line Listen is
Mute
,
-80dB
to
+6dB
.
The range for the Port Input Gain and the Port Output Gain is
-20dB
to
+20dB
.
Содержание KP-4016
Страница 4: ...Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05 4 KP Series...
Страница 8: ...Bosch Security Systems Inc Technical Manual 8 KP Series Rev 05 F 01U 304 914...
Страница 12: ...Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05 12 KP Series...
Страница 160: ...160 Basic Operation KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...
Страница 184: ...184 Firmware Download KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...
Страница 264: ...264 Telephone Interface TIF Operation KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...
Страница 268: ...268 Keypad Quick Reference KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...
Страница 288: ...288 KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05 Input Power 100 240VAC 50 60Hz...
Страница 292: ...292 KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...
Страница 302: ...302 KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...
Страница 306: ...Bosch Security Systems Inc 12000 Portland Avenue South Burnsville MN 55337 U S A www boschcommunications com...