96 Basic Operation
KP Series
Bosch Security Systems, Inc.
Technical Manual
F.01U.304.914 Rev. 05
Keypanel Mirroring (Control Package Only)
Keypanel Mirroring
allows a licensed keypanel (licensed as a supervisor) to take control of a target keypanel. All KP-Series
keypanels can be the target of mirroring, whereas only licensed keypanels can be the supervisor of a target keypanel. By
default, Keypanel Mirroring is disabled. You must enable a panel to be a mirror supervisor in AZedit. This allows any licensed
keypanel to initiate a mirroring operation on a local target.
IMPORTANT:
Mirroring is not supported between trunked intercoms.
Keypanel Mirroring operates in real-time, meaning when a supervisor keypanel initiates a mirroring operation almost all
aspects of the target keypanel functionality are accessible. Once the configuration file is transferred from the target to the
supervisor keypanel, the supervisor keypanel looks and behaves like the target. Turning keys on/off, adjusting key volumes or
panel volumes on either the target or supervisor keypanel is seen immediately on the other keypanel.
NOTE:
If a KP-5032 mirrors a KP-4016 or a DKP-4016, it does not take on the 1RU or desktop aspects.
On the target keypanel, the keypad is locked out, preventing the target keypanel from entering the menu. Any changes to the
configuration made by the supervisor keypanel are immediately transferred to the target keypanel.
IMPORTANT:
The Supervisor keypanel can change settings for features the Target is licensed for, even if the
Supervisor is not licensed for those same features. Compression ratios, additional noise gate settings,
and the 5-band equalizer settings are all available in the Supervisor (even if it is not licensed for these
features) as long as the Target panel is licensed for them. For example, if the target keypanel supports a
5-band EQ and the supervisor keypanel does not, the supervisor keypanel is able to change the EQ
settings.
In AZedit, if a keypanel is a mirror Supervisor or Target, an icon is shown in the Port Status area in the Keypanel View.
IMPORTANT:
If you make changes, including real time changes, to a Target Keypanel using AZedit, those changes are
also seen on the Supervisor Keypanel. However, if you make changes, including real-time changes, to a
Supervisor Keypanel using AZedit, those changes are made to the Supervisor’s saved configuration, but
are not implemented until the Supervisor Keypanel exits Mirroring and returns to normal operation.
Supervisor icon
The Supervisor icon signifies the keypanel is mirroring another keypanel and can
make changes to the other keypanel, known as a Target. For more information, see
“Service Menu, Mirror (Control Package Only)” on page 248.
Target icon
The Target icon signifies the keypanel is being mirrored by another keypanel, known
as a Supervisor. This keypanel is being remotely controlled by the Supervisor. For
more information, see “Service Menu, Mirror (Control Package Only)” on page 248.
****These icons also appear on the keypanels involved in the mirror operation.
Содержание KP-4016
Страница 4: ...Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05 4 KP Series...
Страница 8: ...Bosch Security Systems Inc Technical Manual 8 KP Series Rev 05 F 01U 304 914...
Страница 12: ...Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05 12 KP Series...
Страница 160: ...160 Basic Operation KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...
Страница 184: ...184 Firmware Download KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...
Страница 264: ...264 Telephone Interface TIF Operation KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...
Страница 268: ...268 Keypad Quick Reference KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...
Страница 288: ...288 KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05 Input Power 100 240VAC 50 60Hz...
Страница 292: ...292 KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...
Страница 302: ...302 KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...
Страница 306: ...Bosch Security Systems Inc 12000 Portland Avenue South Burnsville MN 55337 U S A www boschcommunications com...