252 KP-4016/5032 Menu System
KP Series
Bosch Security Systems, Inc.
Technical Manual
F.01U.304.914
Rev. 05
Service Menu, Page Change
Page Change
is used to select whether you are allowed to change setup pages while talk keys are active. By default, in
Standard Intercom Mode, page changes are allowed when talk keys are active. However, the default in Alternate Intercom
Mode does not allow page changes to occur when talk keys are active.
Available options:
Auto
The default is followed depending on the Intercom Mode: Standard or Alternate.
Always Allow
Page changes are allowed while Talk Keys are active.
No Talk Keys
Page changes are not allowed while Talk Keys are active. A red bar appears above/below the
keys signifying page changes are not allowed. If the talk key is turned off, the red bar turns
blue and page changes can be done.
To
configure page change operation
, do the following:
1.
Starting at the Service menu, select
Page Change
.
2.
Press the
SEL button
.
Auto, Always Allow, and No Talk Keys appear in the panel display
.
3.
Using the arrow buttons, select the desired
page change option
you desire.
4.
Press the
SEL button
.
An arrow appears next to the selected option.
Service Menu, Reset Cfg
Reset Cfg
restores almost all custom settings to the defaults and erases all stored autodial numbers. Reset Cfg does not change
the selected alpha size, intercom mode, poll ID, headset transfer state, or reset the IP configuration.
To
reset the keypanel configuration
, do the following:
1.
Starting at the Service menu, select
Reset Cfg
.
Cancel and Do Reset appear in the panel display.
2.
Using the arrow buttons, select
Do Reset
.
3.
Press the
SEL button
.
Configuration Reset appears in the panel display
.
Service Menu, RVON Setup
The
RVON Setup
menu option is used to configure the RVON-I/O IP Address, Netmask Address, and Gateway Address for
the keypanel.
IMPORTANT:
OMNEO and RVON technologies cannot be used at the same time on the same keypanel. Use either
RVON or OMNEO, but not both.
To
configure the IP Address for the RVON-I/O
, do the following:
1.
Starting at the Service|RVON Setup menu, select
RVON-I/O
.
2.
Press the
SEL button
.
IP Address, Netmask, and Gateway appear in the panel display
.
3.
Using the arrow buttons, select
IP Address
.
4.
Press the
SEL button
.
The IP Address appears with the first octet blinking in the display window.
Содержание KP-4016
Страница 4: ...Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05 4 KP Series...
Страница 8: ...Bosch Security Systems Inc Technical Manual 8 KP Series Rev 05 F 01U 304 914...
Страница 12: ...Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05 12 KP Series...
Страница 160: ...160 Basic Operation KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...
Страница 184: ...184 Firmware Download KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...
Страница 264: ...264 Telephone Interface TIF Operation KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...
Страница 268: ...268 Keypad Quick Reference KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...
Страница 288: ...288 KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05 Input Power 100 240VAC 50 60Hz...