30 KP9X Series Keypad Programming
KP-32 User Manual
Bosch Security Systems, Inc.
User Manual
F.01U.193.253
Rev. 16
Keypad Programming, Assigning Setup Pages
1.
Tap the
E-PNL
key.
2.
Select
one
of the four setup pages: tap
1
, or
2
, etc.
3.
Tap the
PGM
key.
4.
Tap any
key
in the row of keys where you want to assign the setup page.
NOTE:
The same setup page cannot be assigned in more than one place. If a setup page is already assigned
somewhere else, you must clear or change that assignment first. With the exception of the main
row assignment, you can clear any page assignment from a row of keys by entering
E-PNL 0
PGM
, then pressing any key in the row.
If you cannot change the setup page assignments for a particular keypanel, this feature may be
restricted in AZedit (Keypanels/Ports screen, Edit button, Setup tab, Setup Page Options).
To display setup page assignments at any time, see “Display Setup Page Assignments” on
page 28.
Keypad Programming, Assigning Intercom Keys
General
There are three methods to assign intercom keys with keypad programming. These methods are summarized below and
explained on the following pages.
Key Assignment using Keypad Numeric Entry: Using this method, you enter the panel number, party
line number etc. that you wish to assign to a key. This method requires that you know the number (not
the name) of the port, party line etc. that you wish to assign. Since most users do not have access to this
information, this method of key assignment is not recommended.
Key Assignment by Copying an Assignment: Using this method, you can copy an assignment from one
key to another. You can also use this method to transfer an incoming call to a talk key and/or listen key.
Key Assignment using Alpha Scrolling: Using this method, you scroll through lists of alpha names in
the
Call waiting
window and select the name of the panel, party line etc. that you want to assign. Then
you copy that name to a key. If descriptive names have been assigned (using the intercom system
configuration software) alpha scrolling is easiest to use.
Assigning Keys Using Keypad Numeric Entry
NOTE:
Each programming step must be completed within 4-5 seconds. Otherwise, the programming sequence
automatically quits.
General Procedure
1.
For talk level 2 assignment only: Tap
0 0
. Otherwise, skip this step.
2.
Select the
key assignment type
:
NUM
Intercom port.
PL
Party line.
AUTO
Auto function.
FUNC SLIST
Special list.
FUNC IFB
IFB
Camera ISO
Содержание EKP-32
Страница 4: ...Bosch Security Systems Inc User Manual F 01U 193 253 Rev 16 iv KP 32 User Manual ...
Страница 12: ...Bosch Security Systems Inc User Manual 8 KP 32 User Manual Rev 16 F 01U 193 253 ...
Страница 14: ...Bosch Security Systems Inc User Manual F 01U 193 253 Rev 16 2 KP 32 User Manual ...
Страница 32: ...20 Basic Operation KP 32 User Manual Bosch Security Systems Inc User Manual F 01U 193 253 Rev 16 ...
Страница 38: ...26 Telephone Operation KP 32 User Manual Bosch Security Systems Inc User Manual F 01U 193 253 Rev 16 ...
Страница 74: ...62 Specifications KP 32 User Manual Bosch Security Systems Inc User Manual F 01U 193 253 Rev 16 ...
Страница 88: ...76 Glossary KP 32 User Manual Bosch Security Systems Inc User Manual F 01U 193 253 Rev 16 ...
Страница 114: ...102 KP 32 User Manual Bosch Security Systems Inc User Manual F 01U 193 253 Rev 16 ...
Страница 120: ...Bosch Security Systems Inc 12000 Portland Avenue South Burnsville MN 55337 U S A www boschcommunications com ...