8.
Press the
SEL button
.
The Delay Time: scroll box appears in the panel display.
9.
Using the arrow buttons,
select the
amount of time
you want to expire before the screen saver becomes active.
To
set the brightness of the display
, do the following:
1.
Starting at the Service|Scrn Saver
menu, select
Display Dim
.
2.
Press the
SEL button
.
The Brightness scroll box appears in the panel display
.
3.
Using the up and down arrow buttons, scroll to the
display brightness
you desire.
To
set the screen saver mode (type)
, do the following:
1.
Starting at the Service|Scrn Saver
menu, select
Mode
.
2.
Press the
SEL button
.
Bitmap, Display Off and Text appear in the panel display.
3.
Using the arrow buttons,
select
Bitmap
to have a bitmap image display when the screen saver activates.
OR
Using the arrow buttons,
select
Display Off
to put the display into sleep mode when the screen saver activates.
OR
Using the arrow buttons,
select
Text
to have a text message display when the screen saver activates.
4.
Press the
SEL button
.
If Bitmap or Text is selected, the options Bounce or Scroll appear.
5.
Using the arrow buttons, select
Bounce
to have the bitmap or text bounce across the display.
OR
Using the arrow buttons, select
Scroll
to have the bitmap or text scroll across the display.
Service Menu, Set Address
Set Address
is used to indicate the poll ID of the keypanel. See “DKP-4016/4016W Addressing” on page 25 to determine if
you need to set the keypanel address. The poll ID is the number (or address) at which an AIO card or intercom attempts to
communicate with the keypanel. The Poll ID number is directly related to the connection port on the breakout panel.
Available options for the Poll ID are
1–8
.
To
set the address
, do the following:
1.
Starting at the Service|Set Address menu, select the
poll ID
for the keypanel.
2.
Press the
SEL button
.
Cancel or Save and Restart appear in the panel display.
3.
Using the arrow buttons, scroll to
Save and Restart
.
4.
Press the
SEL button
.
Restarting.... appears. The keypanel resets. Once the restart is complete, the Poll ID is enabled
.
Содержание DKP-4016
Страница 4: ...Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03 4 DKP 4016...
Страница 8: ...Bosch Security Systems Inc Technical Manual 8 DKP 4016 Rev 03 F 01U 308 248...
Страница 18: ...18 Introduction DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 30: ...30 Installation DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 174: ...174 Firmware Download DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 244: ...244 DKP 4016 Menu System DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 250: ...250 Telephone Interface TIF Operation DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...