228 DKP-4016 Menu System
DKP-4016
Bosch Security Systems, Inc.
Technical Manual
F.01U.308.248
Rev. 03
3.
Using the arrow buttons,
select
Retain
.
4.
Press the
SEL button
.
An arrow appears next to Retain.
Service Menu, Intercom Mode
The
Intercom Mode
menu is used to select the type of firmware you have in your intercom so the keypanel can display alphas
in the correct font/language and modify the behavior of some functions to match the intercom behavior.
Available options are
Alternate
and
Standard
.
NOTE:
Standard mode is the default and should be used in most cases. Alternate mode is primarily used for intercoms
running Japanese firmware.
To
select the intercom mode
, do the following:
1.
Starting at the Service|Intercom Mode menu, select
Alternate
or
Standard
.
An arrow appears next to selected option
.
2.
Press the
SEL button
.
The selections Cancel and Save and Restart appear.
3.
Using the arrow buttons, select
Cancel
to cancel out of the action.
OR
Using the arrow buttons, select
Save and Restart
to save the changes.
4.
Press the
SEL button
.
Service Menu, Key View
The
Key View
menu is used to configure the keypanel keys to show key crosspoint gains, show listen assignments, or show
the matrix for each key assignment.
NOTE:
Show Lstn and Show Mtx are mutually exclusive options. Only one (1) of these options may be enabled at a
time.
Available options for this menu are:
Show Gain
The crosspoint gain bar graph for each key is shown below the talk assignment.
Show Lstn
The listen assignment for each key is shown above the talk assignment.
Show Mtx
The matrix name for each key assignment is shown above the talk assignment.
IMPORTANT:
When the keypanel is configured for 8 Char or 8 Char (Unicode), none of these options are available.
To
configure the Key View
, do the following:
1.
Starting at the Service menu, select
Key View
.
2.
Press the
SEL button
.
Show Gain, Show Lstn, and Show Mtx appear in the panel display.
3.
Using the left and right arrow buttons, select
Show Gain
to show gain on the key display.
OR
Using the left and right arrow buttons, select
Show Lstn
to show listen assignments on the key display.
OR
Using the left and right arrow buttons, select
Show Mtx
to show the matrix assignments on the key display.
4.
Press the
SEL button
.
Disabled and Enabled appear in the panel display
.
Содержание DKP-4016
Страница 4: ...Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03 4 DKP 4016...
Страница 8: ...Bosch Security Systems Inc Technical Manual 8 DKP 4016 Rev 03 F 01U 308 248...
Страница 18: ...18 Introduction DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 30: ...30 Installation DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 174: ...174 Firmware Download DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 244: ...244 DKP 4016 Menu System DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 250: ...250 Telephone Interface TIF Operation DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...