70 Operation
BTR-30N, TR-30N, TR-32N
Factory Reset
Factory Reset
sets the beltpack to Group 1A, channel 1 and
ERASES any user-defined groups in memory. It sets a unit to
factory settings. It also sets the TALK buttons to their default
modes.
To
activate factory reset
, do the following:
>
Press and hold
MENU + SET + UP + DOWN
for two
(2) seconds.
RF Monitor Screen
The
RF Monitor Screen
displays beltpack RF status.
To
display the beltpack RF status
, do the following:
1.
Press and hold
MENU
for two (2) seconds to display
beltpack RF status.
•
If the channel button is set to 1, then signal strength
displays for R1 frequency.
•
If the channel button is set to 2, then signal strength
displays for R2 frequency.
TX Power
Signal Strength
Lo
= 10mW
0= NO
hi
= 50mW
1= Very Weak
2= Weak
3= Moderate
4= Strong
5= Very Strong
2.
Press
MENU
again to exit RF Monitor Screen.
Setting Beltpack ID
Several functions require the beltpack to know which base and
channel it is associated with.
1.
Auto Power Setting: The beltpack reduces its TX power
when close to the base. Beltpack transmit power must be set
to Auto.
2.
Portable Station Deselect: The base can disable the TALK
button of a beltpack. This shuts off the mic in PTT mode
and turns off the transmitter in PT TR mode.
3.
First-On-Latch-Out: This locks a base receive channel so
only one beltpack can transmit on the frequency at a time. A
beltpack user attempting to talk on top of another beltpack
on the same frequency hears a double beep in their headset.
A beltpack tries to establish its ID automatically when its group/
channel changes. The base must be on for this to work.
To
check or set beltpack ID manually
, do the following:
1.
Press and hold
UP
for two (2) seconds.
The LCD displays ID Base# - Receiver#.
For example: ID 1-3 means Base 1, Receiver 3.
If the LCD displays ID--- or does not match the base and
receiver, the beltpack is assigned to, Auto Power, Portable
Station Deselect, and First-On-Latch Out will not work
correctly.
2.
If the beltpack ID is correct, press
MENU
to exit.
3.
If the beltpack ID is not correct, press
SET
.
The ID numbers flash.
4.
Using the UP/DOWN buttons, select a
new ID
.
5.
Press
SET
to apply the new ID.
Bases with transmitters enabled are always base #1. A second
base using the first base transmitters instead of its own, and
properly connected to the first base through CAN bus link
cables becomes base #2, etc.
Содержание BTR-30N
Страница 4: ...4 BTR 30N TR 30N TR 32N...
Страница 20: ...22 Introduction BTR 30N TR 30N TR 32N...
Страница 26: ...24 Installation BTR 30N TR 30N TR 32N...
Страница 73: ...APPENDIX A Additional Resources...
Страница 81: ...BTR 30N TR 30N TR 32N 79 2 Wire Systems Specification...
Страница 89: ...BTR 30N TR 30N TR 32N 87...
Страница 90: ...Bosch Security Systems Inc 12000 Portland Avenue South Burnsville MN 55337 U S A www boschcommunications com...