Einbau- und Betriebsanleitung
Installation and Operating Instructions
Instructions de montage et de service
REact 15E - 8070
- 7 -
08/2013
9
Replacement of components
9.1
Replacing the terminal board
Caution
: Observe the safety regulations
The actuator must be disconnected from the power supply.
•
To replace the terminal board, remove the slide (Fig. 10, pos.520).
•
Remove the board mount from motor plate.
•
Remove the lever-force switch (Fig. 10, pos. 510).
•
Remove the terminal board (Fig. 10, pos. 430) from board mount.
•
Install the new terminal board.
•
Install the lever-force-switch (Fig. 10, pos. 510) onto the pin of the board mount.
•
Secure the lever-force-switch with a quick tension disk.
•
Install the board mount on the motor plate.
•
Install the slide.
•
Perform electrical connection according the wiring diagram.
9.2
Motor assembly replacement
Caution
: Observe the safety regulations
The actuator must be disconnected from the power supply.
•
Disconnect the motor with capacitor from terminal board.
•
Loosen motor screws
•
Replace motor assembly
•
Screw new motor in place and connect plug.
10
Maintenance, repair
The drive is maintenance-free.
The drive may only be cleaned with mild, soapy water.
Lubricant for the gear and spindle nut:
See technical data in appendix.
11
Notes
•
Use is purposive. The drive may only be used for the intended purpose. Control and shut off drive for control and Shut/Off valves.
•
The electric motor can be operated in this drive at a higher ambient temperature (Limit: refer to technical Data).
•
External metal surfaces can get hot during operation. Do not touch.
•
A safety distance to hot components must be maintained to avoid heat building up.