3
Instruction smoothing:
Software setting range 1~512
Idle current:
DIP switch selection, after the motor stops running for 2 seconds, the
idle current can be set to 50% or 100%, and the software can be set from 1 to 100%.
Alarm output:
1 channel optically isolated output port, default is alarm output, can be
reused as brake control
Communication interface:
USB
2.2 Electrical Specifications
Drive parameter
Minimum value
Typical value
Maximum
unit
Supply voltage
24
-
48
VDC
Output current (peak)
0.5
-
3
A
Control signal conduction current
6
10
15
mA
Step pulse frequency
200K
-
1M
Hz
Step pulse width
500
-
-
ns
Direction signal width
5
-
-
us
Undervoltage protection point
-
20
-
VDC
Overvoltage protection point
-
55
-
VDC
Input signal voltage
3.3
5
7
VDC
Drive initialization time
-
-
2
S
3 ports and wiring
The wiring diagram is as follows: