NTRODUCTION
This user’s manual describes the operation of the ECAN1000HR CAN bus Interface
board.
Features
Some of the key features of the ECAN1000HR include:
•
SJA1000 CAN-network controller, Electrically compatible with the
PCA82C200 stand-alone CAN controller chip
•
1 Mb/s maximum data rate (fully programmable)
•
Full CAN-functionality 2.0 B
•
Extended receive buffer (64 byte FIFO)
•
16 MHz clock frequency
•
Galvanically isolated physical interfaces
•
I/O mapped host interface using three addresses
•
-40 to +85C operational temperature
•
+5V only operation
•
PC/104 compliant
The following paragraphs briefly describe the major features of the
ECAN1000HR. A more detailed discussion in included in Chapter 4
(Hardware description) and in Chapter 5 (Board operation and program-
ming). The board setup is described in Chapter 2 (Board Settings). A full
description of the Philips SJA1000 CAN-controller is included in Chapter
5 (Board operation and programming).
CAN bus controller
The ECAN1000HR CAN bus interface is implemented using the Philips
SJA1000 controller. This controller supports CAN Specification 2.0. This
versatile chip supports standard and extended Data and Remote frames;
a Programmable Global Message Identifier Mask; 15 message objects of
8-byte Data Length and a Programmable Bit Rate. This fully integrated
chip supports all the functionality of the CAN bus protocol. The internal 64
byte receive FIFO is ideal for block mode data transfer from the CAN
controller chip.