ECAN1000 User’s Manual
15
BDM-610020026 rev B
J12 Galvanically isolated CAN bus connector
Table 3 below shows the CAN physical interface connector pinout. This
connector is to the right hand side of your board marked J12. The pinout con-
forms to the ISO 11898/2 standard specification.
PIN number
Function
1
N.C.
2
GND_isolated
3
BUS_L
4
BUS_H
5
GND_isolated
6
N.C.
7
N.C.
8
+5V-isolated
9
GND-isolated
10
N.C.
Table 3: J12 CAN Bud Connector
9
7
5
3
1
I_GND
N.C.
I_GND
BUS_L
N.C.
N.C.
I_+5V
N.C.
BUS_H
I_GND
10
8
6
4
2
Table 4: Physical interface connector J12 pinout of the ECAN1000HR
J34 Galvanically isolated CAN bus termination jumper
The jumper marked as J34 is the CAN bus termination jumper. Only two
termination jumpers should be closed at the endpoints of the CAN bus.
Failure to do so may degrade the performance of the bus and it will affect
the bus timing characteristics of the CAN bus. The maximum guaranteed
drive capability of the CAN bus transceiver is 32 nodes.