Document Number

:  ELM0092  A  

Release Date

:  

October 2, 2018 

 

 

 

Field PC

2

 Windows OS 

Update Guide

Содержание Ultra-Rugged Field PC2

Страница 1: ...ion contained in this document RST Instruments Ltd reserves the right to change the information at any time and assumes no liability for its accuracy Copyright 2018 RST Instruments Ltd All rights rese...

Страница 2: ...te version to download 2 Figure 2 2 Selecting the language and downloading the software 2 Figure 2 3 Windows Mobile Device Center the device is connected 3 Figure 2 4 Windows Mobile Device Center sele...

Страница 3: ...INTRODUCTION This document provides step by step instructions for users to update the Window operating system OS on the RST Ultra Rugged Field PC2 FIGURE 1 1 THE FIELD PC2 NOTE IT IS IMPORTANT TO BAC...

Страница 4: ...ndows Mobile based device Field PC2 and a computer 1 On a laptop or PC visit https support microsoft com en ca help 931937 description of windows mobile device center 2 Scroll down to Download Windows...

Страница 5: ...deo folder and Mobile Device Settings 2 2 ACCESSING FILES ON THE FIELD PC2 1 Once the Windows Mobile Device Center is installed connect the Field PC2 to the laptop or PC via USB The status of the conn...

Страница 6: ...PERMANENTLY LOST 2 4 RESTORING DEFAULT FACTORY SETTINGS 1 Connect the Field PC2 to the power adaptor and a power source CAUTION THE FIELD PC2 MUST BE CONNECTED TO A POWER SOURCE IN ORDER FOR THE UPGRA...

Страница 7: ...A RST Instruments Ltd Page 5 FIGURE 2 5 THE POWER BUTTON 4 Using the stylus or a finger slide the Set Factory Defaults to Yes then click Exit Figure 2 6 The Field PC2 will restart FIGURE 2 6 RESETTING...

Страница 8: ...load the following file http www rstinstruments com customersupport downloads FieldPC Archer 2 OS Current English zip 7 Once download is complete unzip the downloaded file 8 Run Archer 2 OS XXX Englis...

Страница 9: ...restart Set the correct time and date when the Date Time dialog appears Click OK and wait for the process to finish 11 A message will appear asking the user to verify the correct OS version has been i...

Страница 10: ...C2 Windows OS Update Guide ELM0092 A RST Instruments Ltd Page 8 2 5 VERIFYING THE OS VERSION 1 Once the device has rebooted select System Info on the Home Screen Figure 2 10 FIGURE 2 10 SELECTING SYST...

Страница 11: ...Field PC2 Windows OS Update Guide ELM0092 A RST Instruments Ltd Page 9 2 Select System ID to expand the menu Figure 2 11 FIGURE 2 11 SELECTING SYSTEM ID...

Страница 12: ...version is accurate install data from the backup 5 Set the correct time and time zone 6 Download the current RST software installation files from the RST Instruments website https www rstinstruments...

Страница 13: ...Field PC2 Windows OS Update Guide ELM0092 A RST Instruments Ltd Page 11 FIGURE 2 13 BLUETOOTH ICON...