83
Dynamics
Dynamics
When the LIMITER popup is displayed, the limiter can be
adjusted using the EQ area controls for the CHANNEL EDIT
section. The FREQ, and GAIN knobs for EQ LO and HI are
disabled at this time. The parameter that you can manipulate
using the EQ area is as follows.
In the LIMITER popup, the function buttons perform the following
operations.
You can recall limiter settings from the library, or store the current
limiter settings in the library.
The LIMITER LIBRARY popup is used to perform limiter library
operations.
1.
Access the LIMITER popup.
fig.PopLmt.eps
2.
Press [F4 (LIBRARY)] to access the LIMITER LIBRARY
popup.
fig.ScrLmtLibGuide.eps
A.
Channel indication
This indicates the channel to which the LIMITER LIBRARY
popup applies.
B.
Library data list
This is a list of the library data.
In the LIMITER LIBRARY popup, the function buttons perform
the following operations.
* Available only for the User library.
For details on library operations, refer to “Library operations”
(p. 39).
Knob
Parameter
EQ LO-MID
Q
Blink
Threshold level
FREQ
Blink
ATTACK time
GAIN
Blink
RELEASE time
EQ HI-MID
Q
Unlit
Disabled
FREQ
Blink
KNEE
GAIN
Unlit
Disabled
Button
Function
[F1 (LIMITER ON)]
Turns the limiter on/off.
[F4 (LIBRARY)
Accesses the LIMITER LIBRARY popup.
[F5 (PEAK CLEAR)]
Clears the level meter’s peak hold or over
indication.
[F8 (CLOSE)]
Closes the popup.
Using the limiter library
Button
Function
[F1 (PRESET)]
Displays the recall-only PRESET li-
brary.
[F2 (USER)]
Displays the USER library, which lets
you recall or store data.
[F3 (PREVIEW)]
Previews (auditions) the library data
that is selected in the list.
[F4 (RECALL)]
Recalls the library data that is selected
in the list.
[F5 (STORE)]*
Stores settings to the library data that
is selected in the list.
[F6 (LOCK)]*
Locks the library data that is selected
in the list.
[F7 (NAME EDIT)]*
Accesses the NAME EDIT popup for
editing the name of the user library
data that is selected in the list.
[F8 (CLOSE)]
Closes the popup.
A
B
M-380_e1.book 83 ページ 2010年6月30日 水曜日 午前10時31分