4.5 Complete service of tool changer
We recommend a complete service on tool changers to be carried out every 5 years. This will
ensure proper function and increase the lifespan of the tool changer considerably. We further
recommend that the maintenance shall be carried out by qualified RSP personnel. Please
contact us for a quotation.
The 5 year tool changer service at Robot System Products includes inspection and cleaning of
the full unit, replacement of all wear parts including sealings and signal pins.
4.6 Replacement of tool changer
Recommended tools
Tools
Applications
Complete set of Allen keys
For dismounting and mounting of tool
changer
Torque wrench
For all socket head cap screws
Dismounting the tool changer
Action
Note
1
Safety
Read the safety section (1.1).
2
Dismount tool
Leave tool, with tool attachment
mounted, in tool stand.
3
Service position
Place the robot in service position.
NOTE!
The tool change function shall
be in locked position.
4
Power off
Switch the power off and lock the circuit
breaker.
NOTE!
Read the safety chapter for the
robot.
5
Pneumatic air off
NOTE!
The pressure in the pneumatic
system must be released before
dismounting begins.
6
Dismount hoses
Dismount the air hoses from the tool
changer.
NOTE!
Make sure that no dirt enters
into the air hoses.
7
Release electrical connectors
(TC5-4E only).
NOTE!
Handle the contact with care, as
it is sensitive to mechanical damage.
Make sure that no dirt enters the
contacts.
Содержание P1001
Страница 2: ...2 M0109 1 ver 2 2 ...
Страница 16: ...16 M0109 1 ver 2 2 2 1 7 Circuit diagram E0211 006 for P1003 ...
Страница 17: ...M0109 1 ver 2 2 17 2 1 8 Circuit diagram E0211 007 for P1004 ...
Страница 36: ...36 M0109 1 ver 2 2 ...
Страница 37: ...M0109 1 ver 2 2 37 ...
Страница 38: ...38 M0109 1 ver 2 2 ...